The AirTAC AirTAC 4V430P-15CI Solenoid Valve, 5/3-way, pressure center, PT1/2, AC110V, grommet entry (4V430P15CI) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with 430P15CI ports and an effective area of 40.0 mm² (Cv 2.35). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V430P-15CI directs compressed air to large double-acting cylinders and actuators with a unique three-position, pressure-center spool. When both solenoids are de-energized, the valve shifts to its center condition where both cylinder ports are simultaneously pressurized, enabling specialized mid-stroke force applications. This 5/3-way configuration uses a double solenoid memory function, meaning the spool holds its last pulsed position without consuming holding current.
Built on the largest 4V body, it delivers an effective area of 40.0 mm² (Cv 2.35) at a maximum cycling rate of 3 cycles per second, suiting pneumatic drives in the Ø80–125 mm range. This specific model is factory-configured for AC110V power via a grommet-style electrical entry with a 0.5-meter flying lead, and its 770-gram aluminum-alloy body achieves a response time of 0.05 seconds or less.
| Model | AirTAC 4V430P-15CI Solenoid Valve, 5/3-way, pressure center, PT1/2, AC110V, grommet entry (4V430P15CI) |
|---|---|
| Series | 4V400 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | 430P15CI |
| Exhaust port | 430P15CI |
| Effective area (Cv) | 40.0 mm² (Cv 2.35) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 770 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 40.0 mm² |
|---|---|
| Flow coefficient | Cv 2.35 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 4 | Body size (4V400) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -430P15CI | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.
Uses the pressure-center position to apply balanced force from both sides of a double-acting cylinder, ideal for delicate part clamping in woodworking or assembly fixtures where a spring return would be too aggressive.
Controls large-bore actuators in test stands requiring a controlled, pressurized mid-stroke state. The 5/3 pressure-center spool allows a specimen to be pre-loaded from both directions before a test sequence begins.
Manages the pilot operation of large forming press cylinders. The pressure-center condition can counterbalance a heavy platen, preventing an uncontrolled drop during an emergency stop without needing a full lockout.
Select the 4V430P-15CI when your application requires a cylinder to be actively pressured from both sides at rest, such as in a balanced holding or opposed-force clamping setup. As the largest 4V series valve, it is the go-to choice for driving bore sizes from roughly 80 mm up to 125 mm; for smaller cylinders, stepping down to a 4V300 (Cv 1.65) typically provides a better fit and faster cycle times. If your flow demand exceeds the 4V400's capacity, consider moving to a larger valve series or a manifold assembly.
When replacing an existing unit, match five key points: the 4V400 body size, the 5/3 pressure-center function, the 1/2-inch port size, the AC110V coil voltage, and the grommet (flying lead) electrical entry. The PT (Rc) tapered thread on this model ensures a tight, reliable seal in standard piping systems.
Quick checklist
In its center position (both solenoids off), the valve pressurizes both cylinder ports (A and B) while blocking the exhaust. This applies system pressure to both sides of a double-acting piston, creating a balanced force state. It is distinct from a closed center, which blocks all ports to hold position, or an exhaust center, which vents both ports to let the cylinder float.
Yes, the 'C' voltage code designates an AC110V 50/60 Hz coil drawing 4.5 VA, which is compatible with typical single-phase control power. The 'I' in the code stands for a grommet-style electrical entry, providing a 0.5-meter pre-wired flying lead instead of a terminal box, which can simplify wiring into a tight machine envelope.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.