The AirTAC AirTAC 4V430P-15F Solenoid Valve, 5/3-way, pressure center, PT1/2, DC12V, terminal entry (4V430P15F) is a genuine 5/3-way 5/3 double solenoid — pressure center solenoid valve with 430P15F ports and an effective area of 40.0 mm² (Cv 2.35). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V430P-15F is a 5/3-way double-solenoid valve that directs compressed air to large double-acting cylinders, and its pressure-center spool applies supply pressure to both cylinder ports simultaneously when neither solenoid is energized. This balanced-pressure neutral is ideal for applications where you need to counteract external forces or prevent a vertical load from drifting slightly without locking it rigidly—it keeps both sides of the piston under force.
Built on the largest 4V body, this DC12V model draws just 2.5 W of coil power and switches within 0.05 seconds. The 4V400 platform delivers an effective area of 40.0 mm² (Cv 2.35) for 5/3 functions, suiting it to cylinders in the ~Ø80–125 mm range. At 770 g, the aluminum-alloy body includes a manual override and supports manifold assembly.
| Model | AirTAC 4V430P-15F Solenoid Valve, 5/3-way, pressure center, PT1/2, DC12V, terminal entry (4V430P15F) |
|---|---|
| Series | 4V400 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Pressure center |
| Port size | 430P15F |
| Exhaust port | 430P15F |
| Effective area (Cv) | 40.0 mm² (Cv 2.35) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 770 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 40.0 mm² |
|---|---|
| Flow coefficient | Cv 2.35 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 4 | Body size (4V400) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -430P15F | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V410 (single), 4V420 (double), 4V430C/E/P (5/3 center). Add the voltage suffix when ordering.
The pressure-center spool keeps both sides of a large clamping cylinder energized at rest, maintaining grip force on a workpiece without continuous solenoid power.
Counteract the weight of a heavy tooling plate or vertical slide by pressurizing both cylinder ports in the center position, reducing the holding current needed from a servo or brake.
Directs air to double-acting cylinders up to Ø125 mm on material-handling gantries and lift-assist devices, where the 40.0 mm² effective area provides the necessary fill rate.
Choose the 4V430P-15F when your double-acting cylinder needs a controlled neutral state with both sides under pressure—common in pressing or clamping operations where you want to maintain force without energizing a solenoid. For smaller cylinders around Ø50–63 mm, the 4V300 series provides a more appropriately sized Cv of 1.65. Since the 4V400 is the largest body in the 4V family, applications demanding higher flow than its 40.0 mm² effective area should look to a larger valve series or a manifolded group of valves.
This is a double-solenoid 5/3 valve, so it requires two control signals and holds its last commanded position on power loss. When matching a replacement, verify all five points: 4V400 body size, 5/3 pressure-center function, 1/2-inch PT (Rc) tapered thread ports, DC12V coil voltage, and the terminal-box electrical entry.
Quick checklist
In the unactuated center position, both cylinder ports (A and B) are connected to supply pressure. This applies force to both sides of the piston, creating a balanced, pressurized neutral that resists external movement without locking the cylinder.
With an effective area of 40.0 mm² (Cv 2.35) and a 3 cycles/sec max frequency, the 4V430P-15F is typically paired with double-acting cylinders in the ~Ø80–125 mm range on pneumatic systems filtered to 40 µm.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.