Genuine AirTAC din rail manifold, order code 6HV100M14F from the 6HVM range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
For a bank of 13 to 14 AirTAC 6HV100 manifold solenoid valves, the 6HV100M14F provides a 315 mm standard DIN rail that carries the valves with a shared supply and exhaust. Like every 6HV100M code above 10 stations, it is specified with two supply and exhaust modules fitted one at each end, and the Dia 10 push-in connections feed valves that offer M5 or 1/8 in. ports. The longer rail is what the two extra valve stations beyond a 12F bank occupy.
Note that AirTAC discontinued the 6HV series in January 2026 without naming a successor. Request a quote with the order code and we will confirm whether this rail can still be supplied.
| Order code | 6HV100M14F |
|---|---|
| Product | DIN Rail Manifold |
| Series | 6HV100M, for 6HV100 valves |
| Stations | 13 to 14 valves (14F) |
| Rail length | 315 mm |
| Rail | Standard DIN rail |
|---|---|
| Supply / exhaust | Push-in Φ8 (6HV0500M), Φ10 (6HV100M) |
| Valve ports | M5 (6HV0500), M5 or 1/8" (6HV100) |
| Stations | 2 – 24 |
| Supply modules | One up to 10 stations, two above 10 |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), DIN rail ordering code and dimensions. AirTAC lists the 6HV series as discontinued (January 2026).
14F covers 13 to 14 valves. Below it, 6HV100M12F carries 11 to 12 valves on the shorter 280 mm rail; above it, 6HV100M16F takes 15 to 16 valves on a longer rail. All three sit above the 10-station threshold, so each runs two supply and exhaust modules. Match the code to your exact valve count so the rail length and the valve spacing stay right, and remember that only the 6HV100 valve family mounts on this rail.
A 13 to 14 valve bank suits conveyor lines running multiple divert or stopping actuators from one shared Dia 10 push-in supply and exhaust.
Groups the valves driving fill, seal and eject cylinders onto one 315 mm rail with a single exhaust path back to the panel.
For banks longer than 10 stations, the two supply and exhaust modules keep feed pressure stable at the last valve, not just at the inlet end.
Rail for 13 to 14 AirTAC 6HV100 valves (code 14F), 315 mm standard DIN rail, Dia 10 push-in supply and exhaust connections, valve ports M5 or 1/8 in., and two supply and exhaust modules because the bank is above 10 stations.
The 6HV series was discontinued by AirTAC in January 2026 and no replacement series has been named. Ask for a quote with the order code 6HV100M14F so we can confirm whether this rail can still be supplied.