Genuine AirTAC manifold solenoid valve, order code 6HV130P06A050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The 6HV130P06A050 orders an AirTAC 6HV manifold solenoid valve on the 100 series body with 1/8" PT supply and outlet ports, set up as a 5/3-way valve with a pressure center (30P). In neutral, pressure is maintained to both cylinder ports, which holds a double-acting cylinder in place with balanced pressure - useful where a load must not sag when the coil is de-energized. The 5/3-way 100 series flows 8.0 mm2 (Cv 0.47), cycles up to 3 cycles/s and runs from 0.2 to 0.8 MPa on 40 um filtered air.
Its plug-in AC220V coil draws 1.1 VA (Class F, tolerance +15%/-10%) and responds in 0.05 s or less, with a 0.5 m lead, and the valve mounts on a DIN rail manifold with common supply and exhaust. The 6HV series is discontinued (January 2026) with no replacement named by AirTAC, so request a quote with this order code to confirm whether it can still be supplied.
| Order code | 6HV130P06A050 |
|---|---|
| Product | Manifold Solenoid Valve |
| Body and port | 100 series, 1/8" PT |
| Function | 5/3-way pressure center (30P) |
| Voltage and lead | AC220V (A), 0.5 m lead |
| Function | 5/2 and 5/3-way manifold solenoid valve |
|---|---|
| Operation | Pilot operated (solenoid) |
| 0500 series | M5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13) |
| 100 series | M5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47) |
| Fluid | Air (filtered by 40 µm element) |
| Operating pressure | 0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to +70 °C |
| Max frequency | 5 cycles/s; 5/3-way 3 cycles/s |
| Body | Aluminum alloy |
| Lubrication | Not required |
| Coil voltages | AC220V, AC110V, DC24V, DC12V |
| Coil power | AC 1.1 VA · DC 0.7 W |
| Voltage tolerance | AC +15% / -10%, DC ±10% |
| Insulation | Class F, dust-protected |
| Electrical entry | Plug-in connector |
| Response time | 0.05 s or less |
Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).
This code combines three choices from the 6HV ordering table: the 1 port size (1/8" PT) rather than the M5 port of 6HV130PM5A050, the 30P pressure center rather than 30C closed or 30E exhaust center, and AC220V (code A) rather than DC24V (B), AC110V (C) or DC12V (F). The datasheet also lists G and NPT threads via codes G and T if PT does not match your pipework. Keep the 0.5 m lead (050), or order 6HV130P06A200 when the coil must be wired from 2.0 m away.
A pressure-center 5/3 valve keeps balanced pressure on a small vertical cylinder in neutral, so a lifted fixture or mast load does not drift when the AC220V coil is off.
Holding pressure to both ports in neutral locks a workpiece clamp in position between cycles, with 1/8" PT ports plumbing cleanly into machine air circuits.
On a DIN rail manifold with common supply and exhaust, an AC220V 5/3 valve cycles stoppers or pushers at up to 3 cycles/s from standard factory mains control.
5/3-way pressure center (30P) on the 100 series body with 1/8" PT supply and outlets: flow 8.0 mm2 (Cv 0.47), operating pressure 0.2 to 0.8 MPa, proof pressure 1.2 MPa, temperature -20 to +70 C, air filtered to 40 um, max frequency 3 cycles/s, response 0.05 s or less. AC220V coil at 1.1 VA, Class F, plug-in entry with a 0.5 m lead.
No - AirTAC discontinued the 6HV series in January 2026 and has not named a replacement series. Send a quote request with the order code 6HV130P06A050 and we will confirm whether this valve can still be supplied.