verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 6HV · Manifold Solenoid Valve

Airtac 6HV Manifold Solenoid Valve 6HV130P06A050

Genuine AirTAC manifold solenoid valve, order code 6HV130P06A050 from the 6HV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Body and port100 series, 1/8" PT
  • Function5/3-way pressure center (30P)
  • Voltage and leadAC220V (A), 0.5 m lead
  • Function5/2 and 5/3-way manifold solenoid valve
  • OperationPilot operated (solenoid)
  • 0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
$50.00 $57.50Save 13%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 6HV body and port, function, voltage and lead on one page All 6HV codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 6HV Manifold Solenoid Valve 6HV130P06A050

The 6HV130P06A050 orders an AirTAC 6HV manifold solenoid valve on the 100 series body with 1/8" PT supply and outlet ports, set up as a 5/3-way valve with a pressure center (30P). In neutral, pressure is maintained to both cylinder ports, which holds a double-acting cylinder in place with balanced pressure - useful where a load must not sag when the coil is de-energized. The 5/3-way 100 series flows 8.0 mm2 (Cv 0.47), cycles up to 3 cycles/s and runs from 0.2 to 0.8 MPa on 40 um filtered air.

Its plug-in AC220V coil draws 1.1 VA (Class F, tolerance +15%/-10%) and responds in 0.05 s or less, with a 0.5 m lead, and the valve mounts on a DIN rail manifold with common supply and exhaust. The 6HV series is discontinued (January 2026) with no replacement named by AirTAC, so request a quote with this order code to confirm whether it can still be supplied.

Airtac 6HV Manifold Solenoid Valve 6HV130P06A050 Technical Specifications

Order code6HV130P06A050
ProductManifold Solenoid Valve
Body and port100 series, 1/8" PT
Function5/3-way pressure center (30P)
Voltage and leadAC220V (A), 0.5 m lead
Function5/2 and 5/3-way manifold solenoid valve
OperationPilot operated (solenoid)
0500 seriesM5 supply and outlets · 3.4 mm² (Cv 0.2), 5/3-way 2.2 mm² (Cv 0.13)
100 seriesM5 or PT1/8 supply and outlets · 8.9 mm² (Cv 0.52), 5/3-way 8.0 mm² (Cv 0.47)
FluidAir (filtered by 40 µm element)
Operating pressure0.15 – 0.8 MPa (21 – 114 psi); 5/3-way 0.2 – 0.8 MPa
Proof pressure1.2 MPa (175 psi)
Temperature-20 to +70 °C
Max frequency5 cycles/s; 5/3-way 3 cycles/s
BodyAluminum alloy
LubricationNot required
Coil voltagesAC220V, AC110V, DC24V, DC12V
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
Electrical entryPlug-in connector
Response time0.05 s or less

Source: AirTAC 6HV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6HV series as discontinued (January 2026).

How to choose

This code combines three choices from the 6HV ordering table: the 1 port size (1/8" PT) rather than the M5 port of 6HV130PM5A050, the 30P pressure center rather than 30C closed or 30E exhaust center, and AC220V (code A) rather than DC24V (B), AC110V (C) or DC12V (F). The datasheet also lists G and NPT threads via codes G and T if PT does not match your pipework. Keep the 0.5 m lead (050), or order 6HV130P06A200 when the coil must be wired from 2.0 m away.

Applications

forklift

Load-holding lift column

A pressure-center 5/3 valve keeps balanced pressure on a small vertical cylinder in neutral, so a lifted fixture or mast load does not drift when the AC220V coil is off.

factory

Machine tool clamping

Holding pressure to both ports in neutral locks a workpiece clamp in position between cycles, with 1/8" PT ports plumbing cleanly into machine air circuits.

conveyor_belt

Conveyor stop and diverter

On a DIN rail manifold with common supply and exhaust, an AC220V 5/3 valve cycles stoppers or pushers at up to 3 cycles/s from standard factory mains control.

FAQ

What are the main specifications of the 6HV130P06A050?

5/3-way pressure center (30P) on the 100 series body with 1/8" PT supply and outlets: flow 8.0 mm2 (Cv 0.47), operating pressure 0.2 to 0.8 MPa, proof pressure 1.2 MPa, temperature -20 to +70 C, air filtered to 40 um, max frequency 3 cycles/s, response 0.05 s or less. AC220V coil at 1.1 VA, Class F, plug-in entry with a 0.5 m lead.

Is the 6HV130P06A050 still sold?

No - AirTAC discontinued the 6HV series in January 2026 and has not named a replacement series. Send a quote request with the order code 6HV130P06A050 and we will confirm whether this valve can still be supplied.