Genuine AirTAC manifold base, order code 7V0500M6F from the 7V0500M range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
For a bank of 6 valves, the AirTAC 7V0500M6F is a 6-station manifold base: it gathers 6 7V0500 solenoid valves onto a common supply and exhaust with PT1/8 ports, for 7V0510, 7V0520 and 7V0530C/E/P valves, threaded or push-in (J). Its overall length L is 82.5 mm. One supply and one exhaust serve the whole bank, which saves space and cost and makes faults easy to trace.
The base comes with seals and screws; unused stations are closed with a blank plate kit (P-7V0500M-R2, plate and screws), ordered separately. It works on air filtered to 40 um at -10 to +50 C. Push-in (J) 7V0500 valves have oval bottom ports and are used only on a base like this one.
| Order code | 7V0500M6F |
|---|---|
| Product | Manifold Base |
| Stations | 6 stations (6F) |
| Port thread | PT1/8 |
| Fits valves | 7V0510 / 7V0520 / 7V0530 |
| Stations | 1 – 20 |
|---|---|
| Supply / exhaust port | PT1/8 |
| Length L | 35 mm (1F), 40.5 mm (2F), +10.5 mm per further station |
| Fits | 7V0510, 7V0520 and 7V0530C/E/P |
| Fluid | Air (filtered by 40 µm element) |
| Temperature | -10 to +50 °C |
| Blank plate | P-7V0500M-R2 |
| Included | Base, seals, screws |
Source: AirTAC 7V series datasheet P84, manifold specifications, dimensions and ordering code.
Order one station per valve: this 6F code takes 6 valves; 7V0500M5F and 7V0500M7F are the next sizes. From two stations on, each further station adds 10.5 mm (L 35 mm for 1F, 40.5 mm for 2F). Leaving a spare station closed with a blank plate makes it easy to add a valve later. The base must match the valve body: 7V0500M takes 7V0500 valves only. G (BSPP) and NPT ports are marked G and T.
Carries 6 7V0500 valves with common PT1/8 supply and exhaust.
Push-in (J) 7V0500 valves need a base like this one for supply and exhaust.
Keeps valves, tubing and wiring together in one place.
Manifold base for 6 7V0500 valves (code 6F); common supply and exhaust PT1/8; length L 82.5 mm; includes seals and screws; blank plate P-7V0500M-R2; air filtered to 40 um, -10 to +50 C.
7V0500 series valves only: 7V0510, 7V0520 and 7V0530C/E/P, threaded or push-in (J). Other 7V bodies need their own base (7V0500M, 7V100M, 7V200M or 7V300M).