This model is discontinued
AirTAC has phased out the ACP series. You can still order this code here: we ship the current replacement ACE32X70SB, the same code under the new prefix. Check its drawing for mounting dimensions before you fit it. The ACE is a current-production ISO 21287 compact cylinder; the ACP followed the older DIN short-body format, so the mounting dimensions differ. Check the ACE drawing before ordering; the comparison table on this page lists what changed.

The AirTAC ACP Compact Cylinder ACP32X70SB is a double acting DIN-standard tight/compact air cylinder with a Ø32mm bore and 70mm stroke, 1/8" air ports and a hard-anodized aluminium body. This model is discontinued — the current-production replacement is the ACE32X70SB (ISO 21287 ACE), the same code after the prefix; check its drawing for mounting dimensions before you fit it.
A double acting compact cylinder built to the DIN-standard short-body format, the ACP32X70SB pairs a 32 mm bore with a 70 mm stroke and a male-threaded 12 mm rod. Push force is 402.1 N and pull force 345.6 N at 0.5 MPa, rising to 563 N on extension at 0.7 MPa. The hard-anodized aluminium body with an S45C hard-chrome rod runs on 0.15-1.0 MPa (22-145 psi) of filtered air at 30-500 mm/s, with fixed TPU bumpers at both ends.
Because the short ISO 21287-class body saves roughly 50% of the mounting length of an ISO 15552 profile cylinder, it slots into tight jigs, guarding and gantry frames where a full-length body will not fit. The S in the code means the optional -S magnet is fitted, so CMSE or DMSE reed and solid-state switches can be clamped on for end-of-stroke signalling. Note this model is discontinued: the current-production replacement is ACE32X70, and buyers should confirm ISO 21287 mounting dimensions before swapping.
| Model | Airtac ACP Compact Cylinder ACP32X70SB |
|---|---|
| Series | ACP DIN compact cylinder (discontinued) |
| Replacement | ACE32X70SB |
| Bore size | Ø32 mm |
| Stroke | 70 mm |
| Acting type | Double acting |
| Port size | 1/8" |
| Rod thread | M10×1.25 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.15 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +80 °C |
| Speed range | 30 – 500 mm/s |
| Cushion | Fixed bumper (both ends) |
| Max standard stroke | Up to 300 mm |
Specifications follow the official AirTAC ACP datasheet (now discontinued); the table below compares them with the ACE32X70SB (ISO 21287) in the 2026A catalog. Confirm mounting-interface dimensions against the ACE datasheet before installation. Rod type: female thread (blank) or male thread (B). ACP thread options: PT (blank) / G / NPT (T).
Old column: AirTAC ACP catalog (discontinued). New column: AirTAC 2026A catalog, ACE series. Values are shown as each catalog prints them for Ø32 mm.
| Item | ACP32X70SB (ACP catalog) | ACE32X70SB (2026A catalog) |
|---|---|---|
| StandardChanged | DIN | ISO 21287 |
| Operating pressureChanged | 0.1–1.0 MPa | 0.15–1.0 MPa |
| Proof pressure | 1.5 MPa | 1.5 MPa |
| TemperatureChanged | -20 to 80 °C | -20 to 70 °C |
| Speed range | 30–500 mm/s | 30–500 mm/s |
| Stroke toleranceChanged | 0–150 mm: +1.0/0; over 150 mm: +1.4/0 | up to 100 mm: +1.0/0; over 100 mm: +1.5/0 |
| Cushion | Bumper | Bumper |
| Port size | 1/8 | PT1/8 |
| Standard strokes / max. stroke (mm)Changed | 5–300 / 300 | 5–200 / 200 |
| Mounting stylesChanged | Basic, FA, FB, CA, CB, LB | Basic, FA, FB, CA, CB, CR (with CB), FTC (with TCM2), LB, SDB (with CA) |
| Rod end codesChanged | Female (blank), B: male, N: no thread | Female (blank), B: male |
| Sensor switchesChanged | CS1-G / DS1-G | CMSE / DMSE |
| Body square BChanged | 50 mm | 49.5 mm |
| Rod Ø D | 12 mm | 12 mm |
| Rod thread (B, male) | M10×1.25 | M10×1.25 |
We ship the ACE32X70SB, the same code after the prefix. The ACP was built to DIN and the ACE to ISO 21287, so the mounting dimensions differ: check the ACE32X70SB drawing before you fit it, and order sensors and brackets with the ACE32X70SB codes.
| Pressure | Push force | Pull force |
|---|---|---|
| 0.5 MPa | 402 N | 346 N |
| 0.7 MPa | 563 N | 484 N |
| Max (@1.0 MPa) | 82 kgf | |
Theoretical force from the ACP bore and rod. Actual usable force is lower than theoretical; size with a margin.
| ACP | DIN compact cylinder (double-acting, discontinued). |
|---|---|
| 32 | Bore size in mm. |
| ×70 | Stroke length in mm. |
| S | Optional built-in magnet for sensor position sensing (omit for no magnet). |
| B | Rod type: B = male thread; blank = female thread. |
Replacement mapping (swap P for E): ACP→ACE, ASP→ASE, ATP→ATE, ACPD→ACED, ACPJ→ACEJ. ACP-family: ACP (double acting), ASP / ATP (single acting push / pull), ACPD (double rod), ACPJ (double rod, adjustable stroke).
The short body and 402.1 N push at 0.5 MPa make this a fit for drill jigs and welding fixtures where a full-length profile cylinder will not fit behind the clamp arm.
With the -S magnet fitted, CMSE or DMSE switches confirm each 70 mm eject stroke on assembly lines sorting plastic housings or stamped brackets.
Size both ways: if 402.1 N of push at 0.5 MPa is more than the job needs, the 25 mm bore (245.4 N) saves space; if the load needs more, step up to the 40 mm bore at 628.3 N. The 70 mm stroke sits well inside the 200 mm standard range for this bore, so no made-to-order stroke is required. Choose LB foot or FA/FB flange mounts for fixed fixtures, or CA/CB clevis plus an I/Y knuckle where the rod must articulate. Remember that a plain cylinder drifts when air is lost - add a rod lock or pilot check valve if the load must be held. Order ACE32X70 as the current replacement and verify the ISO 21287 mounting footprint first.
AirtacDistr lists every ACP32 order code with its price on one page at https://airtacdistr.com/products/airtac-acp32-compact-air-cylinder
Replacement checklist
At 0.5 MPa it pushes 402.1 N and pulls 345.6 N; at 0.7 MPa push rises to 563 N and pull to 483.8 N, with a theoretical maximum of 82 kgf at 1.0 MPa. The rod is 12 mm with a male thread (B code), the air port is 1/8" PT, and the 70 mm stroke is within the 200 mm standard range for this bore. Operating pressure is 0.15-1.0 MPa (22-145 psi) with a 1.5 MPa (215 psi) proof pressure.
Order ACE32X70, the current-production ISO 21287 successor: swap the P for an E and you get the same 32 mm bore, 70 mm stroke and force class in a matching short body. The male rod thread and 1/8" port carry over, but because the ACP was DIN-standard, confirm the ISO 21287 mounting dimensions against your fixture before swapping. If you need switch feedback, check whether the ACE variant you order carries the magnet option for CMSE / DMSE switches.
Send us the quantity and destination. We confirm price, availability and lead time on the ACE32X70SB replacement — usually within 7 hours.