The AirTAC Airtac AFR Air Filter Regulator AFR2000MJNWG is a genuine A/B-line filter regulator with PT1/4" ports. It is the compact air-preparation line, regulating 0.15 - 0.9 MPa (20 - 130 psi) with a push-to-lock knob. Flow is confirmed from the datasheet on request.
The AFR2000MJNWG is an AirTAC compact A-line filter regulator: a single body that both removes water and particulate from compressed air and reduces the downstream pressure to your set point. This configuration carries a manual drain, a 5 um filter element (the finer W grade, compared with the standard 40 um), the standard pressure type, and no gauge - useful when the panel already has its own pressure indicator. It is built for a G1/4 (BSPP) port, the 2000C size of the compact family, and handles a maximum inlet/working pressure of 1.0 MPa (145 psi) with a regulation range of 0.15-0.9 MPa (20-130 psi). Temperature range is -5 to 70 C, non-freezing. This is a genuine AirTAC part from the compact A/B line, not the larger G/GA series. The A-line 2000C body is one of four sizes - 1500C (1/8 in), 2000C (1/4 in), 3000C (3/8 in) and 4000C (1/2 in) - with the B-line bodies above them for larger ports. Because flow is not published as a single rated figure, we confirm the datasheet flow figures for AFR2000MJNWG on request before you order.
| Model | Airtac AFR Air Filter Regulator AFR2000MJNWG |
|---|---|
| Type | Filter Regulator |
| Line | A-line (compact A/B air preparation) |
| Port size | PT1/4" (G (BSPP) thread) |
| Filter grade | 40 um standard, 5 um optional (W) |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) (low-pressure type to 0.4 MPa) |
| Fluid | Compressed air |
|---|---|
| Max. inlet pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 C (non-freezing) |
| Bowl material | PC (polycarbonate) |
| Pressure drop | Low (catalogue-stated) |
Specifications follow the official AirTAC A/B-line air-preparation data. Drain type, filter grade, gauge and low-pressure options are set by the model-code suffix - see the description. Flow curves, weight and outline dimensions are not published in our data set — ask us and we confirm from the factory datasheet.
Decodable choices for this family: A-line (1/8 to 1/2 in) or B-line bodies by port size and required flow; drain as differential-pressure + manual (default) or automatic (A code); filter element 40 um standard or 5 um (W); standard type or low-pressure type (L, max 0.4 MPa); gauge included by default or omitted (N), with scale options MPa, psi, bar or kgf/cm2 and psi; thread as PT (standard) or G (BSPP) or NPT. The MJNWG suffix of this model selects manual drain, no gauge, the 5 um element and the G thread. Flow is not a single rating, so ask us to confirm sizing against the datasheet before ordering.
Feeds filtered, regulated air to a small bench-mounted pneumatic press or riveting tool, where the 5 um element protects the valve and cylinder seals and the manual drain is bled off at shift end.
Supplies clean, regulated air to the gripper and vacuum-ejector circuit of a compact pick-and-place module, with the pressure set point read from the panel's own gauge since no gauge is fitted here.
Prepares air for the cylinders and air jets of a labeling or taping head on a packaging conveyor, where water carry-over and fine particulate would otherwise foul the quick exhaust and jet nozzles.
AirTAC does not publish flow for this compact A/B-line unit as a single rated number, so we do not quote one. The datasheet flow figures for the 2000C size are available on request - contact us and we will confirm them so you can size the unit against your line's air demand.
Yes. The N code means the gauge is omitted, but the self-locking adjustment knob and the 0.15-0.9 MPa (20-130 psi) regulation range work exactly as on gauge-equipped units. If you would rather have a gauge on the body, we can quote the same filter regulator with a gauge in MPa, psi, bar or kgf/cm2 and psi scale.