The AirTAC Airtac ATE Single Acting Guided Compact Cylinder ATE20X5B is a genuine single acting, pull (spring return) ISO 21287 compact air cylinder with a Ø20mm bore and 5mm stroke, M5×0.8 air ports and a hard-anodized aluminium body. Its short compact envelope saves about 50% of the mounting length of an ISO 15552 profile cylinder.
This AirTAC ATE20X5B is a single acting pull cylinder with a spring return, so the spring extends the rod and air retracts it, delivering a net pull of 88.1 N at 0.5 MPa. Its compact ISO 21287 body is about 50% shorter than an ISO 15552 profile cylinder, making it ideal for tight spaces in automated assembly fixtures.
The hard-anodized aluminium body and S45C hard-chrome plated rod resist wear in continuous cycling. The fixed TPU bumper at both ends absorbs energy, and the male rod thread (B code) simplifies attachment. With a 5 mm stroke, this unit is suited for precise, short indexing tasks, and the 0.2 MPa minimum working pressure ensures reliable operation even with low-pressure shop air.
| Model | Airtac ATE Single Acting Guided Compact Cylinder ATE20X5B |
|---|---|
| Series | ATE compact cylinder |
| Standard | ISO 21287 |
| Bore size | Ø20 mm |
| Stroke | 5 mm |
| Acting type | Single acting, pull (spring return) |
| Port size | M5×0.8 |
| Rod thread | M6×1.0 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.2 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 50 – 500 mm/s |
| Cushion | Fixed TPU bumper (both ends) |
| Max standard stroke | Up to 25 mm |
Specifications follow the official AirTAC ACE-series (ISO 21287) datasheet. Body: hard-anodized aluminium alloy; piston rod: S45C carbon steel with hard-chrome plating. Rod type: female thread (blank) or male thread (B). Thread options: PT (blank) / G. A built-in magnet is OPTIONAL — add the -S code to fit CMSE / DMSE position sensors.
| Pressure | Pull force (spring return) |
|---|---|
| 0.5 MPa | 88.1 N |
| 0.7 MPa | 135.2 N |
Single-acting pull: the spring extends the rod; air retracts it. Forces already net the spring; minimum working pressure is 0.2 MPa. Single-acting strokes are short (Ø12 to 10 mm, Ø16-100 to 25 mm).
| ATE | ISO 21287 compact cylinder (single-acting pull, spring-return). |
|---|---|
| 20 | Bore size in mm. |
| ×5 | Stroke length in mm. |
| S | Optional built-in magnet for CMSE / DMSE sensors (omit for no magnet). |
| B | Rod type: B = male thread; blank = female thread. |
ACE-family variants: ACE (double acting), ASE / ATE (single acting push / pull), ACED (double rod), ACEJ (adjustable stroke), TACE / TACED (non-rotating twin-guide yoke). Mounting accessories: FA / FB flange, LB foot, CA / CB clevis, CR, SDB pivot, FTC; plus I and Y knuckles. Thread PT (blank) / G.
Use the 88.1 N pull to retract a locating pin in a CNC fixture, holding a small bracket during drilling. The short 5 mm stroke provides fast, repeatable pin withdrawal.
In a packaging line, this cylinder can retract a spring-loaded gate to release a single carton. The 5 mm stroke is enough to clear the path, and the spring return resets it for the next cycle.
Actuate a small pneumatic valve lever in a lab test rig. The 88.1 N pull at 0.5 MPa is sufficient for the valve's low operating force, and the compact body fits within the instrument's tight enclosure.
For a lighter pull, consider the 16 mm bore ATE16X25 with 53.3 N at 0.5 MPa, while the 25 mm bore ATE25X25 offers a stronger 170.9 N pull. This 20 mm bore model with an 88.1 N pull is a balanced choice for small parts handling. The spring returns the rod to its extended position on air loss, so it does not hold a mid-stroke position. Mounting options include FA/FB flange, LB foot, CA/CB clevis, and SDB pivot brackets, and the optional -S magnet can be ordered for CMSE or DMSE sensors.
Quick checklist
The ATE20X5B provides a net pull force of 88.1 N at 0.5 MPa and 135.2 N at 0.7 MPa, with the spring force already subtracted. The minimum working pressure is 0.2 MPa, and the maximum is 1.0 MPa (145 psi).
No, this model does not have a magnet, so it cannot be used with CMSE or DMSE sensors. To use sensors, you must order the model with the optional -S code, such as ATE20X5SB, which includes the built-in magnet for switch mounting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity and destination. We confirm price, stock and lead time — usually within 7-8 hours.