verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W

The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$168.49 $176.36Save 4% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W

GC400C10AC1W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator that condition compressed air in three stages. This 400-size set is fitted with PT3/8 (3/8 in.) ports, a 5 um filter element for finer particle and water removal, an automatic drain that empties the filter bowl without operator attention, and an external round pressure gauge reading in MPa. The 400-size bowls are polycarbonate, and the set is rated for compressed air at up to 1.0 MPa (145 psi) inlet.

This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with 1/8 in. to 1 in. ports. Drain types, filter grades, gauge scales and G (BSPP) or NPT threads are catalogue options, and a bracket can be ordered for panel mounting. AirTAC publishes flow for this series as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W Is Used

precision_manufacturing

CNC machining center air supply

Feeds the tool-changer, chip-blower and clamping circuits of a machining center with filtered, regulated and lubricated air, using the 5 um element and automatic drain to keep the supply clean during unattended runs.

science

Test rig and laboratory bench air

Conditions the compressed air feeding a QC test bench or laboratory fixture, where the 5 um grade and a readable MPa gauge help operators hold a consistent, particle-free supply to sensitive instruments.

factory

Automotive paint shop supply line

Serves a paint-shop air header ahead of spray stations: the filter with automatic drain removes water and fine dirt, the regulator sets gun pressure and the lubricator conditions downstream air tools.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W the Right Station?

Work through the G-series steps - sizes 200 to 600 with ports from 1/8 in. to 1 in. - to match the air demand of the line; the 400 size with PT3/8 ports is the mid-to-large step for headers feeding several actuators. This version pairs an automatic drain with a 5 um element, the finer of the two grades (40 um is standard), plus an external round MPa gauge; a manual-drain version widens the regulator adjustment range to 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) here. PT is the standard thread, with G (BSPP) and NPT orderable as specifications. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W FAQ

AirTAC publishes flow for the G series as curves rather than one rated number, so we do not quote a single figure here. Send us your line pressure and air demand and we will confirm the datasheet curve and sizing on request before you order.

GC combines three separate bodies - filter, regulator and lubricator - so each stage is serviced or replaced on its own. This version adds an automatic drain, a 5 um element and an external round MPa gauge; drain type, filter grade and gauge scale can all be re-selected in the code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10AC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC400C10AC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.