The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10ANW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC400C10ANW is a genuine AirTAC GC-series three-unit F.R.L. combination: a separate filter, pressure regulator and lubricator assembled as one set. This code is 400 size with a PT3/8 port (PT thread is the standard; G and NPT threads are catalogue options), a 5 um filter element (W), an automatic drain (A) on the filter bowl, and no gauge fitted (N). It removes water and particulate down to 5 um, lets you set downstream pressure anywhere in the 0.15-0.9 MPa (20-130 psi) adjust range, and meters oil mist into the line for downstream tools and cylinders. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. At 400 size the filter and lubricator bowls are polycarbonate.
The G series spans 200, 300, 400 and 600 sizes, so ports step from 1/8" up to 1" within the same family, and drain type, filter grade, gauge scale and thread are all orderable options. Published flow data for the series appears as curves rather than one rated figure, so ask us and we will confirm the datasheet figures for this exact code on request.
| Model | Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10ANW |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to a machining centre's pneumatic clamps, tool-change cylinders and chip doors; the 5 um element and automatic drain keep water and fine particulate away from the machine's valves.
Powers tape heads, case erectors and box kickers along a packaging conveyor; the lubricator oils fast-cycling cylinders and the automatic drain keeps condensate out of the sealers.
Supplies impact wrenches, nutrunners and air balancers at automotive trim stations; automatic drainage suits bays where nobody checks bowls between shifts.
Choose 400 size when your line's demand suits a 3/8" port; step up to 600 or down to 300/200 as flow and porting require - larger sizes carry larger ports and more flow. The 5 um element (W code) is the finer of the two catalogue grades (40 um is standard) and suits points of use with sensitive valves. The A code automatic drain empties the bowl without operator attention, which matters where bowls sit high or drains are easily missed. No gauge is fitted, so pick a C or F coded variant with the scale you want if operators must read set pressure. Thread is PT as standard; order G (BSPP) or T (NPT) if your pipework needs it. Flow is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes G-series performance as flow curves, not as a single rated figure, so we do not quote a number here. Tell us your required flow and working pressure and we will confirm the datasheet curve for this exact code on request before you order.
The N in the code means no gauge is fitted. The GC family normally includes an embedded square gauge, and an external round gauge in MPa, psi or bar scales is an orderable option, so choose a C or F coded variant such as GC400C10C1 when operators need to read the set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.