The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10C1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC400C10C1W is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator, set up for 3/8 in PT ports at the 400 size. The three units clean, regulate and oil-mist lubricate the compressed air line in sequence. This configuration carries the W 5 um filter element, the default differential-pressure drain on the filter bowl, a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, and a round external pressure gauge reading in MPa. Maximum inlet pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C (non-freezing), and the 400-size filter and lubricator bowls are PC (polycarbonate).
The G series spans sizes 200, 300, 400 and 600, so this same function set is available with smaller or larger ports. Filtration grade, drain type (differential-pressure, automatic or manual), gauge style and thread (PT standard, with G and NPT as catalogue options) can all be selected within the series. AirTAC publishes flow for this size as curves rather than a single rated figure, so ask us to confirm the flow and datasheet figures for your application.
| Model | Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10C1W |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeding filtered, regulated and lubricated air to the clutch, counterbalance cylinders and die cushions of a mechanical stamping press in a metalworking shop.
Conditioning the supply to spray guns and air-driven agitators in a refinish booth, where clean, regulated, oil-misted air supports consistent finish quality.
Supplying the tool-change actuators, air blast and workholding circuits on a CNC machining center, keeping moisture and debris out of downstream valves.
Step up to the 400 size when your circuit needs 3/8 in ports and more air than the 300 size passes; the 600 size goes larger still. Drain choice matters: this unit uses the default differential-pressure drain, while automatic (A) and manual (M) versions are available to order, and a manual-drain unit widens the regulator range to 0.05-0.9 MPa (7-130 psi). Filtration here is the finer 5 um W element; the 40 um standard element suits general plant air.
The C1 code selects a round external gauge in MPa; psi and bar scales, or the embedded square gauge (F codes), are catalogue alternatives. Thread is PT as standard, with G (BSPP) and NPT as options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for the GC400 size as characteristic curves, not as a single rated figure, so we do not quote a number here. Tell us your operating pressure and air demand and we will confirm the flow and datasheet figures for this model on request.
The standard grade on the GC series is 40 um, which suits general plant air. The W option on this model reduces filtration to 5 um for finer protection of directional valves, cylinders and spray equipment. Both grades are catalogued on the same GC400 body.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.