The AirTAC Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10MNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC400C10MNW is a three-unit AirTAC F.R.L. combination: a separate filter, pressure regulator and lubricator assembled as one set. This version is sized 400 with 3/8 in PT ports, carries a 5 um filter element (grade W) and a manual drain, and is supplied without a gauge. Maximum inlet pressure is 1.0 MPa (145 psi) and the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). The filter bowl on the 400 size is polycarbonate, and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um standard or 5 um (W) elements, gauge options and PT, G (BSPP) or NPT threads. Published flow data appears as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC400C10MNW |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Filter, regulate and lubricate the supply to a press cylinder on a stamping line, with the manual drain suited to a station that is inspected each shift.
The 5 um element conditions shop air ahead of spray guns and atomizing lines where a finer grade than the standard 40 um is preferred.
Filtered, regulated, oil-mist-lubricated air feeds the directional valves and cylinders that drive a packaging machine's conveying and sealing motions.
Choose the size by required flow: 200 to 600 step up in port and capacity, with the 400 body and 3/8 in ports suiting mid-size circuits. Drain choice matters: the manual drain here needs periodic draining but allows the widest regulator adjustment, 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drains raise the bottom of the range to 0.15 MPa (20-130 psi). The 5 um element suits cleaner-air duties, while 40 um is the standard grade. Gauge codes, PT versus G/NPT threads and bracket options complete the configuration.
Because rated flow is published as curves rather than a single number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm sizing from the datasheet on request.
A manual drain is opened by an operator at intervals, which suits attended stations. It also allows the widest regulator adjustment range, 0.05-0.9 MPa (7-130 psi), versus 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains. Automatic-drain versions are available in the series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.