Genuine AirTAC three-unit frl, order code BC40004 from the AC-BC range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
For PT1/2 supply lines read in mixed units, the BC40004 order code configures AirTAC's largest B-line set - BF4000C filter, BR4000C regulator and BL4000C lubricator - with the dual kgf/cm2 and psi gauge scale that the trailing 4 selects in the ordering table. It is the standard-pressure, standard-element version of the BC4000.
It regulates 0.15 - 0.9 MPa (20 - 130 psi) and accepts a maximum working pressure of 1.0 MPa (145 psi) with 1.5 MPa (215 psi) proof pressure over -5 to +70 C (no freezing). Drain is differential plus manual, the standard B-line arrangement; the filter bowl holds 60 cc and the lubricator 90 cc, using ISO VG32 turbine oil. The GS40 gauge arrives on the dual kgf/cm2 and psi scale.
| Order code | BC40004 |
|---|---|
| Product | Three-Unit FRL |
| Model and port | BC4000 · PT1/2 |
| Drain · type | Differential + manual drain · Standard, max 0.9 MPa |
| Gauge · element · thread | Gauge in kgf/cm² & psi · 40 µm element · PT thread |
| Models | AC1500, AC2000, BC2000, BC3000, BC4000 |
|---|---|
| Port | AC1500: PT1/8, AC2000: PT1/4, BC2000: PT1/4, BC3000: PT3/8, BC4000: PT1/2 |
| Thread | PT (standard), G, NPT (T) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Drain bowl capacity | A1500/A2000: 15 cc · B2000/B3000: 40 cc · B4000: 60 cc |
| Lubricator capacity | A1500/A2000: 25 cc · B2000/B3000: 60 cc · B4000: 90 cc |
| Components | AF1500C filter + AR1500C regulator + AL1500C lubricator; AF2000C filter + AR2000C regulator + AL2000C lubricator; BF2000C filter + BR2000C regulator + BL2000C lubricator; BF3000C filter + BR3000C regulator + BL3000C lubricator; BF4000C filter + BR4000C regulator + BL4000C lubricator |
| Fluid | Air |
| Regulating range | 0.15 – 0.9 MPa (20 – 130 psi) |
| Low-pressure (L) version | up to 0.4 MPa (58 psi) |
| Maximum pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -5 to +70 °C (no freezing) |
| Recommended oil | ISO VG32 turbine oil |
| Gauge | GS40 on gauge versions |
Source: AirTAC AC/BC series datasheet (p.274, 2025-11 edition, airtac.com), ordering code and specifications.
Among the three BC4000 codes listed, BC40004 is the one to order for a PT-thread 1/2 line where the panel is read in kgf/cm2 and psi and the standard 40 um element is sufficient. BC40001W shares the PT thread but carries the 5 um W element and an MPa dial, while BC40003G switches to G thread with a bar gauge. If a PT3/8 port is large enough for the flow, the smaller BC3000 covers the same standard-pressure 0.15 - 0.9 MPa range.
The 1/2 PT port feeds high-consumption circuits such as large valves and air tools, with the standard 40 um element suiting general shop air.
Cylinder-driven conveying and diverting lines can be conditioned by one 60 cc-bowl set, lubricated with ISO VG32 oil from the 90 cc reservoir.
Teams working from both metric and imperial drawings can set and verify pressure on the kgf/cm2 and psi dial without carrying a conversion table.
BC4000 body with PT1/2 port, built from BF4000C filter, BR4000C regulator and BL4000C lubricator; standard 40 um element; GS40 gauge on a kgf/cm2 and psi scale; drain bowl 60 cc and lubricator 90 cc; regulating range 0.15 - 0.9 MPa (20 - 130 psi); maximum pressure 1.0 MPa (145 psi); proof pressure 1.5 MPa (215 psi); -5 to +70 C; differential plus manual drain.
Both are standard-pressure BC4000 sets on a PT1/2 port with differential plus manual drain, but BC40004 keeps the standard 40 um element and reads the GS40 gauge in kgf/cm2 and psi (trailing digit 4), while BC40001W adds the W option for a 5 um element and uses scale 1, an MPa dial.