The AirTAC Airtac CMSG Reed Switch Sensor CMSG-030 is a genuine CMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a 2-wire output on 5-240 V AC/DC with a 3 m flying lead. It only works on a cylinder that carries a piston magnet.
This is the general-type CMSG-030, a reed magnetic position switch from AirTAC. The reed element is a sealed mechanical contact that snaps closed when the magnet built into the cylinder piston reaches the switch position - no electronics, no amplifier, just a contact. Output is 2-wire for series wiring, the operating supply spans 5-240 V AC or DC with no polarity, protection is IP64, and the unit arrives with a 3 m flying lead ready to cut back to length.
A practical point: at 5 V DC low-voltage levels a reed contact needs no load-wiring fuss, while at 240 V AC it slots directly into older relay control panels - one switch covering both worlds. The G profile is the mounting-fit code and must correspond to the sensor groove of your cylinder; confirm the pairing with your cylinder model. The switch reads nothing by itself, so the cylinder must be ordered with the magnet option fitted.
| Model | Airtac CMSG Reed Switch Sensor CMSG-030 |
|---|---|
| Family | CMS — Reed switch cylinder sensor |
| Technology | Reed (magnetic contact) |
| Output | 2-wire |
| Outputs in this family | 2-wire contact |
| Lead / connector | 3 m flying lead |
| Supply voltage | 5-240 V AC/DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | G (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
A reed contact switches a wide window, 5-240 V AC or DC, which is why it suits AC circuits and relay logic. IP64. The CMS range has no RW / IP68 option - that belongs to DMS and EMS. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| CMS | Reed switch cylinder sensor — reed (magnetic contact). |
|---|---|
| G | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| 030 | 3 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. On a CMS the suffix -H is the high-temperature version — do not confuse it with the H profile letter. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | CMSG · 2-wire · 5-240 V AC/DC |
|---|---|
| Consider DMS | the solid-state range with NPN / PNP 3-wire outputs (DC only) |
| Consider EMS | the mini 2-wire solid-state switch (DC only) |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
Detects full extension of the diverter cylinder on a parcel-sort conveyor, its 2-wire contact feeding a legacy 230 V AC relay panel without interface modules.
Confirms mould closure on a block-making press where the dusty plant environment and simple AC control wiring favor a sealed mechanical reed contact.
Tracks arm position on automatic car-wash gantries, with the 3 m lead routed back to a washdown-rated control cabinet outside the wet zone.
Pick CMSG-030 if your control circuit is AC, mixed AC/DC, or a wide DC window, and you want the simplest possible position feedback: a two-wire contact in series with the load. It is the general-type CMS - if the location is hot, step up to the -H variant. For a DC PLC input where bounce and contact wear matter, an electronic DMS or EMS is the better match. The 3 m lead suits control boxes mounted a short run from the cylinder; longer runs use the 5 m or 10 m versions or a connector type. Match the G profile to the cylinder groove, and confirm the piston magnet is fitted.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
It is a reed position switch with a 2-wire contact output, rated for 5-240 V AC or DC supply with no polarity, IP64 protected, and terminated in a 3 m flying lead. It is the general (non-high-temperature) type of the CMS family.
The CMS reed contact wires in series like a mechanical limit switch, accepts AC or DC across 5-240 V, and draws no standby electronics - ideal for relay panels and mixed-voltage machines. An electronic DMS/EMS switch is DC-only and solid-state, with faster bounce-free cycling for PLC counting. Whichever you choose, the G profile must fit your cylinder's sensor groove and the cylinder must have the built-in magnet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.