The AirTAC Airtac CS1M Reed Sensor CS1M020A20 is a genuine CS1 reed (mechanical-contact) magnetic switch, normally open, that senses the piston magnet in a pneumatic cylinder. As a dry 2-wire contact it switches AC or DC across 5-240 V, supplied with a 2 m cable. The M type fits PB, MA, MAL, MI, MF. It carries a red led and is rated IP67.
The AirTAC CS1M020A20 is a reed magnetic switch, normally open, for band-mounting on tie-rod and mini cylinders. It reads the piston magnet and switches AC or DC across 5-240 V, giving one part that fits both AC control gear and a 24 V DC PLC. The 2 m cable carries a red LED for quick setup.
The M type wraps on with a band and its order carries a tube-material and bore code; here an aluminium 20 mm bore. It fits PB, MA, MAL, MI and MF cylinders, has a 100 mA / 10 W contact with no leakage, and is IP67 rated from -10 to 70 C.
| Model | Airtac CS1M Reed Sensor CS1M020A20 |
|---|---|
| Switch kind | Reed contact, SPST, normally open |
| Wiring | 2-wire (Red LED) |
| Supply voltage | 5 - 240 V AC/DC |
| Max switching current | 100 mA |
| Max contact capacity | 10 W (10 VA) |
| Residual voltage | 2.5 V max at 100 mA |
| Connection | 2 m cable |
| Sensitivity | 45-75 Gauss (by bore) |
|---|---|
| Indicator | Red LED |
| Leakage / internal draw | None (dry contact) |
| Max switching frequency | 200 Hz |
| Shock / vibration | 300 / 90 m/s2 |
| Temperature | -10 to 70 C |
| Protection rating | IP67 (NEMA6) |
| Fits (M type) | PB, MA, MAL, MI, MF |
Specifications follow the official AirTAC CS1 data. Band-mount; the order carries a tube-material and bore code. Switching an inductive or lamp load arcs the contact, so add a flyback diode (DC) or RC snubber (AC) to extend life. Exact fit and accessory codes are confirmed from the datasheet on request.
Pick the reed CS1 when AC-or-DC operation, zero leakage or a direct relay/lamp drive matters; pick the solid-state DS1 for very high speed or cycle life. The band-mount M type suits round mini bodies where a clip or groove switch will not seat. Match the material and bore code to your cylinder.
The 10 W contact holds current well under the 100 mA limit at 24 V, so a PLC input sits comfortably in range. Add a flyback diode or RC snubber when the switch drives a coil.
Confirms a small MI clamp has closed on a part before machining starts.
Signals a PB pen cylinder has reached its transfer stop on a light jig.
Counts strokes of an MA cylinder into a PLC for maintenance planning.
It band-mounts: a strap wraps the round body and a set screw locks it. The order carries a tube-material and bore code, here aluminium 20 mm.
Yes, within the 100 mA / 10 W contact rating. For an inductive coil add a flyback diode (DC) or RC snubber (AC) to protect the contact.