The AirTAC Airtac DMSE Electronic Sensor DMSE-030-W is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a 2-wire output on 10-28 V DC with a 3 m flying lead. It only works on a cylinder that carries a piston magnet.
The DMSE-030-W combines AirTAC's electronic solid-state DMS switch, a 2-wire output, a 3 m flying lead and a 10-28 V DC supply in an IP64 enclosure. Clipped into the sensor groove of a magnet-equipped AirTAC cylinder, it closes its circuit as the magnetised piston arrives at the set point.
Its defining letter is the trailing W, a factory variant code not defined in our catalogue data - we will state precisely what it alters once we check the datasheet, and we quote IP64 in the meantime rather than guessing at a higher rating. The E profile letter selects the groove fit, so line it up with your cylinder series before purchase.
| Model | Airtac DMSE Electronic Sensor DMSE-030-W |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | 2-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 3 m flying lead |
| Supply voltage | 10-28 V DC |
|---|---|
| Protection rating | IP64 |
| Version | W - factory special code, confirm from datasheet |
| Profile letter | E (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| E | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| (blank) | Output: 2-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 030 | 3 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| W | W - factory special code, confirm from datasheet. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSE · 2-wire · 10-28 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
Sorting systems that eject parts hundreds of times a minute favour the solid-state output, since a reed contact would bounce and wear under that duty.
On transfer-car or stopper cylinders in a pallet conveyor system, the 3 m lead reaches the control cabinet mounted at the end of the conveyor section.
Leak and function test rigs log cylinder positions via these switches; the 2-wire series connection feeds a monitoring relay without loading the measurement circuit.
Order the DMSE-030-W when your BOM names this variant of the 3 m, 2-wire DMS switch; otherwise the standard DMSE-030 delivers the same 10-28 V DC, IP64 package. For confirmed waterproof, oil-resistant and flex-resistant construction at IP68, ask for the -RW version instead of relying on the W. Fit profile E to the matching cylinder groove, keep the supply within 10-28 V DC, and remember the cylinder must be ordered with the built-in magnet option for the switch to detect anything.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Electronic (solid-state) type, 2-wire output, 10-28 V DC supply, IP64 housing, 3 m flying lead, profile E fit code. The W suffix is an undocumented factory variant we will confirm from the datasheet. Electrical limits such as maximum switching current: confirm from the datasheet.
Electrically they share the 2-wire output, the 10-28 V DC supply, IP64 protection and the 3 m lead. The only difference on paper is the trailing W, whose effect our published data does not define - we will verify it with AirTAC before your order is confirmed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.