The AirTAC Airtac DMSE Electronic Sensor DMSE-N100 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a npn 3-wire output on 5-30 V DC with a 10 m flying lead. It only works on a cylinder that carries a piston magnet.
The DMSE-N100 is a solid-state electronic position switch from AirTAC's DMS range. It senses the piston magnet of an AirTAC cylinder fitted with the magnet option and returns an NPN 3-wire signal on a 5-30 V DC supply. There is no mechanical contact inside, so nothing bounces or wears out under fast cycling. This version ends in a 10 m flying lead, the longest lead in the standard 020/030/050/100 line-up, and the general construction is rated IP64.
The 3-wire NPN output sinks current to the PLC input rather than switching the supply line in series, which gives the input card a cleaner signal than a 2-wire loop and keeps leakage out of the reading. Before ordering, check that the E profile body matches the sensor groove of your cylinder - the letter is a mechanical fit code, not a performance grade. Send us your cylinder series and we will confirm the exact match from the datasheet.
| Model | Airtac DMSE Electronic Sensor DMSE-N100 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | NPN 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 10 m flying lead |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | E (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| E | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| N | Output: NPN 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 100 | 10 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSE · NPN 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
The NPN 3-wire signal connects directly to a sinking DC input card, giving the controller a clean end-of-stroke bit for a pick-and-place sequence.
With 10 m of flying lead, the switch reaches a remote control panel without splicing or extension joints on a wide sorting conveyor.
Mounted in the groove of a magnet-equipped clamping cylinder, it confirms full clamping before a CNC cycle is allowed to start.
Pick an electronic DMS switch when your circuit is DC, cycles quickly, or feeds a PLC input that needs a defined NPN sinking signal; a reed CMS switch suits AC circuits or mixed 5-240 V AC/DC supplies instead. NPN must match the input card type - if your PLC expects a sourcing (PNP) signal, order the P variant rather than adapting in the field. The 10 m flying lead suits long cable runs to a distant control cabinet or a route through a cable track; if the switch sits somewhere you service often, an M8 or M12 connector version lets you unplug instead of rewiring. Whatever wiring you choose, the E profile has to seat correctly in the cylinder groove, and the cylinder itself must be ordered with the built-in magnet option - a switch on an unmagnetised piston never trips.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
It is a solid-state electronic switch with an NPN 3-wire output, powered from 5-30 V DC and rated IP64 in the general construction. The connection is a 10 m flying lead, and the E profile body must match your cylinder's sensor groove. Exact electrical ratings such as load current should be confirmed from the datasheet.
A 3-wire NPN output gives a PLC input a cleaner, more defined signal than a 2-wire switch wired in series with the load, but the input card must be NPN-compatible - otherwise order the PNP version. Also remember the switch only works on a cylinder ordered with the built-in magnet, and the profile letter has to suit that cylinder's groove.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.