The AirTAC Airtac DMSG Electronic Sensor DMSG-P020 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a pnp 3-wire output on 5-30 V DC with a 2 m flying lead. It only works on a cylinder that carries a piston magnet.
The DMSG-P020 is an AirTAC DMS electronic position switch - solid-state, no moving contact - that reads the piston magnet of a suitably equipped AirTAC cylinder and reports end-of-stroke electrically. Its P code gives a PNP 3-wire output for DC PLC inputs, the supply range is 5-30 V DC, the general housing carries IP64, and connection is a 2 m flying lead.
Because a three-wire PNP output drives the input card directly instead of sitting in series with the load, the signal a PLC sees is cleaner than from a two-wire switch - the reason many machine builders reserve the P and N versions for controller inputs. Profile G is a groove-fit code, not a grade: match it to your cylinder body before ordering, and confirm the exact seating with us.
| Model | Airtac DMSG Electronic Sensor DMSG-P020 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | PNP 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 2 m flying lead |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | G (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| G | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| P | Output: PNP 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 020 | 2 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSG · PNP 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
Fitted at full stroke of a clamping cylinder, the PNP output feeds a dedicated PLC input so the controller releases the spindle only after the workpiece is verifiably clamped.
On a vacuum gantry, the switch marks the fully retracted position of the vertical cylinder, preventing arm traverse while the gripper is still down on the part.
A pneumatic stopper on a parcel sorter reports its up state over the 2 m lead, letting the divert gate fire in time for each package.
Pick this model when your circuit is DC and the input card expects a sourcing PNP signal. If your PLC uses sinking NPN inputs, choose the DMSG-N variant instead; if you need polarity-free AC or DC operation, the CMS reed range covers 5-240 V AC/DC with a mechanical contact. The 2 m flying lead suits fixed, cut-to-length wiring; M8 or M12 connector codes are there for frequent unplug-and-service access. The profile letter must seat in your cylinder's sensor groove, and the cylinder itself must carry the built-in magnet option - a bare switch senses nothing.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
It is a solid-state electronic switch with a PNP 3-wire output, a 5-30 V DC supply range, IP64 protection in the general build and a 2 m flying lead. It signals only when mounted on a magnet-equipped cylinder.
PNP sources voltage toward the input; the DMSG-N code sinks it instead. Match the letter to your PLC input card - sourcing inputs want PNP, sinking inputs want NPN. Both detect the same piston magnet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.