The AirTAC Airtac DMSH Electronic Sensor DMSH-050 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a 2-wire output on 10-28 V DC with a 5 m flying lead. It only works on a cylinder that carries a piston magnet.
DMSH-050 is a solid-state electronic position switch from AirTAC's DMS range, set up as a 2-wire device that connects in series with your load and takes its 10-28 V DC across those same two conductors. The 5 m flying lead is the longest standard lead in the family, useful when the control panel is a good distance from the machine. IP64 is the enclosure rating. It signals when the piston of a magnet-equipped AirTAC cylinder passes its mounting point.
Because the 5 m run is already long, this version often saves a splice or junction box on larger frames. Check that profile H corresponds to the sensor groove of your cylinder - the letter is a mechanical fit code, not a performance grade, and the exact cylinder series it suits should be confirmed against your model before you buy.
| Model | Airtac DMSH Electronic Sensor DMSH-050 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | 2-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 5 m flying lead |
| Supply voltage | 10-28 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | H (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| H | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| (blank) | Output: 2-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 050 | 5 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSH · 2-wire · 10-28 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
On a vertical lift unit in a distribution warehouse, the 5 m lead drops from the cylinder down the mast to the drive panel without any joint.
A rotary bottling filler uses the switch to verify filler-valve cylinders are home between cycles, the long lead reaching the control cabinet at the frame base.
Inside a semiconductor wafer handling module, the contactless solid-state output confirms each transfer stroke cleanly, with the 5 m cable routed to the clean-side controller.
Take this 5 m version when distance, not signal conditioning, is the problem: the two-wire loop stays simple at 10-28 V DC and IP64. If the run grows beyond that, switch to an M8 or M12 connector type and use a longer pre-made cable; if a PLC needs NPN or PNP logic, choose the 3-wire DMS output instead. It must be paired with a cylinder carrying the built-in magnet, and profile H has to seat in that cylinder's groove.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
It is an electronic (solid-state) switch, 2-wire output, 10-28 V DC supply, IP64 protection, supplied with a 5 m flying lead. It only produces a signal on an AirTAC cylinder that has the built-in piston magnet.
A flying lead is the simpler, cut-to-length option for one fixed installation. An M8 or M12 connector version is worth it when the switch may need unplugging for service or cable replacement. Profile H must fit the cylinder groove in both cases.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.