The AirTAC Airtac DMSH Electronic Sensor DMSH-N050 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a npn 3-wire output on 5-30 V DC with a 5 m flying lead. It only works on a cylinder that carries a piston magnet.
This DMSH-N050 pairs AirTAC's electronic switch family with a generous 5 m flying lead, letting you route the cable away from hot or moving machine sections back to the control cabinet. The NPN 3-wire output works from a 5-30 V DC supply and sinks into a PLC input card; the body is IP64.
Solid-state switching means no reed contact to wear out and no signal bounce on rapid cycling - a real advantage on palletisers and other high-rate machines. The sensor only sees anything once it is mounted on a cylinder with the built-in magnet option, and the H profile must seat in that cylinder's groove.
| Model | Airtac DMSH Electronic Sensor DMSH-N050 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | NPN 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 5 m flying lead |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | H (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| H | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| N | Output: NPN 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 050 | 5 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSH · NPN 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
On a palletising cell, the 5 m lead lets the switch sit deep in the machine frame while its NPN output reaches the cabinet, confirming the layer pusher is home.
A metal press feed with short strokes cycles the piston magnet hundreds of times a minute; the solid-state output answers without the bounce a reed contact would show.
A test-rig slide driven by an AirTAC cylinder uses the switch as an end-of-travel reference, with the long lead keeping electronics outside the moving envelope.
Decide between families by circuit first: a CMS reed unit handles 5-240 V AC or DC simply, while this DMS electronic model is DC-only but bounce-free for fast cycling. On a 5-30 V DC system with a sinking PLC input, the NPN 3-wire output here is the clean choice. The 5 m lead suits runs that pass near moving parts or reach a distant cabinet; if you prefer tool-free swaps, look at the M8/M12 connector builds instead. Standard sealing is IP64; the -RW version lifts that to IP68. Whichever you pick, the H profile has to fit the cylinder groove and the piston must carry the factory magnet.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Type: electronic solid-state. Output: NPN 3-wire. Supply: 5-30 V DC. Wiring: 5 m flying lead. Protection: IP64 in the general build. It detects the piston magnet of an AirTAC cylinder fitted with the magnet option and nothing else.
It is ideal when the cable must route around moving sections or reach a distant cabinet, and you can trim it to length on site. If the sensor is unplugged often for service or replacement, an M8 or M12 connector version saves rewiring - both are legitimate specification choices.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.