The AirTAC Airtac DMSH Electronic Sensor DMSH-NC08 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a npn 3-wire output on 5-30 V DC. It only works on a cylinder that carries a piston magnet.
An electronic piston-position sensor in AirTAC's DMS series, the DMSH-NC08 uses a solid-state element rather than a mechanical reed. The letter N specifies an NPN 3-wire output for sinking PLC inputs, H is the groove-fit profile, and the C08 token is a factory connection code whose exact termination we will confirm from the datasheet on request. Supply span is 5-30 V DC; the standard housing carries IP64.
Because it is three-wire, the switch hands the controller a referenced signal instead of behaving like a contact in series with the load, which keeps the input state unambiguous. It still needs a partner: an AirTAC cylinder built with the magnet option, whose groove accepts the H profile. Confirm both the cylinder fit and the C08 detail before you wire it in.
| Model | Airtac DMSH Electronic Sensor DMSH-NC08 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | NPN 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | See datasheet |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | H (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| H | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| N | Output: NPN 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 08 | See datasheet. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSH · NPN 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
A transfer unit's slide cylinder, ordered with the magnet option, signals 'home' and 'extended' to the cell PLC; the solid-state output suits the frequent indexing of an assembly station.
On an R&D test bench, the referenced three-wire signal lets engineers log each actuator end position precisely, with the C08 termination matched to the rig's interface once confirmed.
Panels built around sinking digital inputs take the NPN output directly - one wire to supply, one to the input, one common - keeping panel wiring tidy.
This code combines an NPN output with the C08 connection designation - a catalogue variant we do not document in detail, so ask us and we will pull the datasheet. If your panel prefers a sourcing input, the P version is the equivalent PNP part. Electronic switches of this class run on DC only and watch polarity; if your circuit swings between AC and DC or you want a contact-style switch instead, a CMS reed model covers 5-240 V AC/DC. The H profile must match the cylinder groove regardless of which family you choose.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Yes: DMS electronic (solid-state) type, NPN 3-wire output, 5-30 V DC supply, IP64 protection, and the C08 connection code, which we will verify from the datasheet for you. Sensing distance and similar values are not published here - confirm from the datasheet.
It is a factory connection designation in the AirTAC catalogue; the meaning is not in our published data, so we do not guess. Send an RFQ and we will confirm the exact termination from the official datasheet before you order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.