The AirTAC Airtac DMSH Electronic Sensor DMSH-PC12 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a pnp 3-wire output on 5-30 V DC. It only works on a cylinder that carries a piston magnet.
The DMSH-PC12 from AirTAC is a solid-state position sensor with a PNP 3-wire output for magnet-fitted cylinders. It operates from 5-30 V DC and carries IP64 in its general form. C12 is a connection code position that our data leaves undefined; treat it as a factory variant and we will verify the C12 interface from the datasheet on request.
Three-wire PNP gives the PLC a driven, bounce-free signal rather than the small leakage drop a 2-wire switch imposes in series with the load. The H profile again is purely a seating code for the cylinder groove - the catalogue does not map it to specific series, so check the fit with us first.
| Model | Airtac DMSH Electronic Sensor DMSH-PC12 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | PNP 3-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | See datasheet |
| Supply voltage | 5-30 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | H (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| H | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| P | Output: PNP 3-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 12 | See datasheet. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSH · PNP 3-wire · 5-30 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
A pick-and-place gantry uses the signal for the Z-axis down position, and the solid-state output handles rapid repetitive cycling without contact bounce.
On a converting line, it flags when the tension-arm cylinder reaches its correction limit so the drive can re-trim.
With a C12 connection code, this unit suits installations being converted to a pluggable wiring scheme; we confirm the C12 interface from the datasheet for you.
Settle on this switch when a sourcing PLC input is in play and the C12 connection suits your panel's wiring standard, pending datasheet confirmation from us. Against a 2-wire layout, the 3-wire PNP output keeps the input signal cleaner and unaffected by load leakage. Wet or oily locations call for the -RW IP68 variant of the DMS range; hot zones on other machines point to the CMS-H high-temperature reed switch. Do not forget the magnet-option cylinder and the groove-matched H profile.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Electronic solid-state type, PNP 3-wire output, 5-30 V DC supply, IP64 protection in the general version, and a C12 connection code that is not documented in our data - we will verify what C12 specifies from the datasheet on request.
Yes. It only detects a piston that carries a magnet, so the cylinder must be ordered with the built-in magnet option, and the H profile must seat correctly in that cylinder's groove. Send us the cylinder series and we will check the fit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.