The AirTAC Airtac DMSHS Electronic Sensor DMSHS-030 is a genuine DMS magnetic position switch. It senses the magnet ring in a pneumatic cylinder's piston and signals when the piston reaches that point, giving a 2-wire output on 10-28 V DC with a 3 m flying lead. It only works on a cylinder that carries a piston magnet.
The DMSHS-030 belongs to AirTAC's electronic DMS sensor line: a solid-state switch that trips when the magnet in a suitably equipped piston passes its seat. It presents a 2-wire output, accepts 10-28 V DC, seals to IP64, and terminates in a 3 m flying lead - the longest standard bare cable in the range, handy when the nearest terminal rail is a frame-width away. The S directly behind the profile letter H is a factory variant; quote your cylinder series and we will confirm what it denotes from the datasheet.
Three metres of bare cable can be routed through a duct and cut flush at the terminal, avoiding connector blocks altogether. As with every 2-wire electronic switch it behaves like a contact in series with the load, so retrofitting into an existing DC circuit is straightforward. The profile H is a fit code for the cylinder groove, not a grade - and without the factory magnet option the sensor has nothing to read.
| Model | Airtac DMSHS Electronic Sensor DMSHS-030 |
|---|---|
| Family | DMS — Electronic cylinder switch |
| Technology | Electronic (solid-state) |
| Output | 2-wire |
| Outputs in this family | 2-wire, NPN 3-wire or PNP 3-wire |
| Lead / connector | 3 m flying lead |
| Supply voltage | 10-28 V DC |
|---|---|
| Protection rating | IP64 |
| Version | Standard version |
| Profile letter | H (cylinder-groove fit) |
| Profiles in this family | E, G, H, J |
| Detects | Piston magnet ring inside the cylinder |
2-wire versions run 10-28 V DC; NPN / PNP 3-wire versions run 5-30 V DC. IP64 as standard. Order the RW version where coolant, washdown or constant cable flexing is present. Switching distance, response time, current rating, voltage drop, LED behaviour, contact life, weight and dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| DMS | Electronic cylinder switch — electronic (solid-state). |
|---|---|
| H | Profile letter: the mounting / groove type that fits a particular cylinder body. This family offers E, G, H, J. It is a fit code, not a performance grade. |
| (blank) | Output: 2-wire. Blank is 2-wire, N is NPN 3-wire, P is PNP 3-wire. |
| 030 | 3 m flying lead. 020 / 030 / 050 / 100 are 2 / 3 / 5 / 10 m flying leads; M08 and M12 are M8 / M12 connector versions. |
| (blank) | Standard version. |
We do not hold the full profile-to-cylinder-series table, so confirm the profile letter against your cylinder model before ordering — send us the cylinder part number and we will check the fit.
The split is electrical, not quality. Solid-state DMS and EMS are DC-only and suit modern PLC inputs; the reed-based CMS switches a much wider window, so it is the one for AC circuits, relay logic and older panels. The RW (IP68) option exists on DMS and EMS only.
| This switch | DMSH · 2-wire · 10-28 V DC |
|---|---|
| Consider EMS | the mini 2-wire electronic switch for tight installations |
| Consider CMS | the reed alternative for AC circuits and voltages up to 240 V |
| Mounting parts | F-MQ (round body), F-ACT (tie-rod) |
A traverse carriage on an R&D test rig reports its end positions through sensors wired by 3 m leads straight to a bench terminal strip.
On a parcel sorter, each divert arm's cylinder carries a sensor whose long lead reaches the central control rack without any splicing.
Where the cylinder sits two frames away from the panel, the 3 m bare lead is ducted the whole way and trimmed at the terminal - no connector in the vibration path.
Pick this DMS unit when the circuit is DC, the run is long, and a connector would just be cut off anyway. A 3-wire NPN or PNP DMS is the upgrade path for PLC cards that want a dedicated signal; a CMS reed switch is the answer where AC is present or the 5-240 V AC/DC span is needed. Washdown and oil-mist zones belong to the -RW build with its IP68 sealing, not this general type. Above all, the profile letter has to match the groove of your magnet-fitted cylinder - send the series for confirmation.
Quick checklist
Use the F-MQ bracket on round-body cylinders and F-ACT on tie-rod cylinders where there is no groove to seat the switch. Both are ordered separately from the switch. Switching distance and mounting dimensions come from the factory datasheet — ask us for the sheet that matches your cylinder.
Electronic (solid-state) switch type, 2-wire output, 10-28 V DC supply, IP64 general protection, 3 m flying lead. Current, voltage drop and timing figures are not published here - confirm from the datasheet.
No. Lead length is a wiring choice, not an electrical one - the 3 m cable simply reaches a distant terminal point and can be trimmed. What matters electrically is matching the 10-28 V DC supply and, if you step to a 3-wire DMS, choosing NPN or PNP to suit your PLC input.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, your cylinder model (so we can confirm the profile fit) and the destination. We confirm price, availability and lead time — usually within 7-8 hours.