The AirTAC Airtac GAR Air Regulator GAR20008SN is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1/4" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR20008SN is a compact air pressure regulator that takes a higher supply pressure and holds a steady, lower downstream pressure you set with the knob. It is a regulator only - it does not filter the air or remove water, so install a separate filter upstream if the line needs cleaning.
This standard-type unit regulates from 0.05 to 0.9 MPa (7-130 psi) and weighs just 170 g with its 1/4in ports. The pressed-in self-locking knob keeps your pressure setting from drifting when the machine vibrates, and the balanced valve design holds the setpoint as supply pressure varies.
| Model | Airtac GAR Air Regulator GAR20008SN |
|---|---|
| Series | GAR200 air regulator |
| Port size | 1/4" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | None |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 170 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR200 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR200 | GA200 series air regulator — sets the port range and weight class. |
|---|---|
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow (reflux) valve. |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR200-08 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR200 · 1/4" · 170 g |
|---|---|
| One size up | GAR300 |
| Add filtration | GAFR200-08 (filter + regulator) |
Set a steady 0.4 MPa to a pneumatic clamp on a small assembly fixture. The self-locking knob holds the pressure even when the workcell vibrates.
Feed a blow gun or a small air tool at a stable 0.6 MPa from a shop line that fluctuates. The balanced design keeps the outlet pressure from drifting.
Regulate a test jig at 0.3 MPa for repeated actuator cycles. The 170 g body mounts directly to the panel with the included bracket.
Choose the GAR200 body for light-duty circuits with 1/4in piping, such as a single clamp or a small tool. The standard S type covers 0.05-0.9 MPa, while the L type only reaches 0.4 MPa - pick S unless you need fine control in that low band. This model has no gauge, so read pressure on the line's own panel gauge; the included bracket mounts it to a panel or frame. The PT thread suits metric installations, and its gauge scale reads MPa/psi if one is fitted. For clean air, use the matching GAFR200-08 filter-regulator or a GAF filter upstream. The S type's adjustable band is about 2.4x the L type's span (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR200-08 filter-regulator as your air-prep needs grow.
The GAR20008SN regulates air from 0.05 to 0.9 MPa (7-130 psi). Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -20 to 70 C. The unit weighs 170 g and has 1/4in ports.
The N in GAR20008SN means no pressure gauge is fitted. You read the downstream pressure on the line's own panel gauge instead. This saves cost and panel space when a separate gauge is already installed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.