verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAR400 · Air Pressure Regulator

Airtac GAR Air Regulator GAR40015LJNK

The AirTAC Airtac GAR Air Regulator GAR40015LJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.

  • TypeAir regulator
  • Port size1/2"
  • Pressure range0.05 - 0.4 MPa
  • RegulationLower pressure
  • GaugeNone (N)
  • Reflux valveYes (K)
  • Max pressure1.0 MPa
  • Weight570 g
$50.41 $57.50Save 12% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAR Air Regulator GAR40015LJNK

The GAR40015LJNK is an air pressure regulator that takes a higher supply and holds a steady lower downstream pressure. It does not filter, clean, or dry the air, and has no drain bowl or filter element. This 1/2in unit weighs 570 g and uses the lower-pressure type, regulating from 0.05-0.4 MPa (7-58 psi).

The pressed-in self-locking knob prevents the setpoint from drifting due to vibration or accidental knocks. A balanced adjustment mechanism helps it maintain its setting as supply pressure varies. With no gauge fitted, you read the pressure on the line's own panel gauge instead.

Airtac GAR Air Regulator GAR40015LJNK Technical Specifications

ModelAirtac GAR Air Regulator GAR40015LJNK
SeriesGAR400 air regulator
Port size1/2" (PT thread)
Regulation typeLower pressure
Pressure range0.05 - 0.4 MPa (7 - 58 psi)
Pressure gaugeNone (N) — MPa / psi port
BracketNot included (J)
Reflux valveAttached (K)
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-20 to +70 °C
AdjustmentSelf-locking press-in knob
MountingPanel + optional bracket
Weight570 g

Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR400 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.

Model Code: Airtac GAR Air Regulator GAR40015LJNK

GAR400GA400 series air regulator — sets the port range and weight class.
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
LLower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure).
JNo bracket (J) — panel mount or existing bracket.
NNo gauge (N) — for a line with a panel gauge already.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached (K).

A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR400-15 is the same regulator with a built-in filter.

Size Class

  • GAR2001/8"-1/4" · 170 g
  • GAR3001/4"-1/2" · 300 g
  • GAR4003/8"-1/2" · 570 g
  • GAR5003/4" · 580 g
  • GAR6003/4"-1" · 1390 g

All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.

This modelGAR400 · 1/2" · 570 g
One size downGAR300
One size upGAR500
Add filtrationGAFR400-15 (filter + regulator)

Where the Airtac GAR Air Regulator GAR40015LJNK Is Used

precision_manufacturing

Low-pressure pneumatic clamp

Set a delicate clamping force on a fixture where the standard 0.9 MPa range would be too coarse. The L type's finer low band lets you dial in a precise 0.2 MPa hold without over-stressing a thin workpiece.

science

Lab air supply station

Regulate a bench air line for a sensitive instrument that needs a stable 0.3 MPa feed. The balanced valve holds the setpoint as the shop compressor cycles, and the 1/2in port handles the instrument's modest demand.

build

Spray gun pressure control

Feed a manual spray gun with a consistent low pressure for even coating. The self-locking knob keeps the setting fixed during long shifts, while the no-gauge design lets you rely on the gun's own regulator readout.

Is the Airtac GAR Air Regulator GAR40015LJNK the Right Regulator?

Choose the GAR400 body when your line needs a 1/2in port and the 570 g mass suits a fixed panel or bracket mount. The L type regulates only 0.05-0.4 MPa (7-58 psi), so it cannot reach a 0.5-0.6 MPa setpoint at all; pick the S type for standard machine pressures. This model has no gauge (N) and no bracket (J), so plan for a panel mount and an external pressure readout. The PT thread gives an MPa/psi gauge scale, and the K suffix means a reverse-flow (reflux) valve is attached. If the air also needs cleaning, use a GAFR filter-regulator or a GAF filter upstream. The L type's 0.35 MPa band is about 2.4x narrower than the S type's 0.85 MPa span, giving finer low-pressure resolution.

Quick checklist

  • ✓ Body size for your air demand (1/2" here)
  • ✓ Type S (0.05-0.9) or L (0.05-0.4 MPa)
  • ✓ Gauge fitted, or no gauge (N)
  • ✓ Thread PT / G / NPT (sets gauge scale)
  • ✓ Bracket kept or removed (J)
  • ✓ Need filtration too? Use GAFR400
Ask an Engineer

Installation & Setting Notes

  • check Install with the airflow arrow: IN to OUT, knob accessible.
  • check Put a filter (GAF or a GAFR) UPSTREAM — a regulator does not clean the air.
  • check Set pressure by turning the knob up to the target, then press it in to lock.
  • check Keep supply at or below the 1.0 MPa (145 psi) max working pressure.
  • check Never exceed the 1.5 MPa (215 psi) proof pressure.
  • check Support the 570 g unit on its panel or bracket, not on the tubing.

This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR400-15 filter-regulator as your air-prep needs grow.

Airtac GAR Air Regulator GAR40015LJNK FAQ

The GAR40015LJNK regulates air from 0.05-0.4 MPa (7-58 psi) with a lower-pressure type. Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -20 to 70 C. The unit weighs 570 g and has a 1/2in port.

The N means no pressure gauge is fitted. You read the downstream pressure on the line's own panel gauge or an external gauge instead. The J means no mounting bracket is included, so use a panel mount or an existing bracket.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAR Air Regulator GAR40015LJNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAR40015LJNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.