The AirTAC Airtac GAR Air Regulator GAR40015LJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR40015LJNK is an air pressure regulator that takes a higher supply and holds a steady lower downstream pressure. It does not filter, clean, or dry the air, and has no drain bowl or filter element. This 1/2in unit weighs 570 g and uses the lower-pressure type, regulating from 0.05-0.4 MPa (7-58 psi).
The pressed-in self-locking knob prevents the setpoint from drifting due to vibration or accidental knocks. A balanced adjustment mechanism helps it maintain its setting as supply pressure varies. With no gauge fitted, you read the pressure on the line's own panel gauge instead.
| Model | Airtac GAR Air Regulator GAR40015LJNK |
|---|---|
| Series | GAR400 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 570 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR400 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR400 | GA400 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR400-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR400 · 1/2" · 570 g |
|---|---|
| One size down | GAR300 |
| One size up | GAR500 |
| Add filtration | GAFR400-15 (filter + regulator) |
Set a delicate clamping force on a fixture where the standard 0.9 MPa range would be too coarse. The L type's finer low band lets you dial in a precise 0.2 MPa hold without over-stressing a thin workpiece.
Regulate a bench air line for a sensitive instrument that needs a stable 0.3 MPa feed. The balanced valve holds the setpoint as the shop compressor cycles, and the 1/2in port handles the instrument's modest demand.
Feed a manual spray gun with a consistent low pressure for even coating. The self-locking knob keeps the setting fixed during long shifts, while the no-gauge design lets you rely on the gun's own regulator readout.
Choose the GAR400 body when your line needs a 1/2in port and the 570 g mass suits a fixed panel or bracket mount. The L type regulates only 0.05-0.4 MPa (7-58 psi), so it cannot reach a 0.5-0.6 MPa setpoint at all; pick the S type for standard machine pressures. This model has no gauge (N) and no bracket (J), so plan for a panel mount and an external pressure readout. The PT thread gives an MPa/psi gauge scale, and the K suffix means a reverse-flow (reflux) valve is attached. If the air also needs cleaning, use a GAFR filter-regulator or a GAF filter upstream. The L type's 0.35 MPa band is about 2.4x narrower than the S type's 0.85 MPa span, giving finer low-pressure resolution.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR400-15 filter-regulator as your air-prep needs grow.
The GAR40015LJNK regulates air from 0.05-0.4 MPa (7-58 psi) with a lower-pressure type. Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -20 to 70 C. The unit weighs 570 g and has a 1/2in port.
The N means no pressure gauge is fitted. You read the downstream pressure on the line's own panel gauge or an external gauge instead. The J means no mounting bracket is included, so use a panel mount or an existing bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.