The AirTAC Airtac GAR Air Regulator GAR60025SNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR60025SNK is a regulator-only unit that takes a variable supply and holds a steady downstream pressure you set with the knob. It does not filter or clean the air, and it has no drain bowl or filter element. This model carries a 1in port and weighs 1390 g, placing it at the top of the GAR size range for high-demand lines.
Its pressed-in self-locking knob keeps the setpoint from drifting when the machine vibrates, so a calibrated pressure stays put between shifts. The balanced adjustment mechanism also holds the setting as the incoming supply fluctuates, which protects downstream equipment from pressure surprises. A reverse-flow (reflux) valve is attached to this unit.
| Model | Airtac GAR Air Regulator GAR60025SNK |
|---|---|
| Series | GAR600 air regulator |
| Port size | 1" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 1390 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR600 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR600 | GA600 series air regulator — sets the port range and weight class. |
|---|---|
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) only. |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR600-25 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR600 · 1" · 1390 g |
|---|---|
| One size down | GAR500 |
| Add filtration | GAFR600-25 (filter + regulator) |
Set a stable 0.6 MPa for a stamping press header that feeds multiple pneumatic cylinders, keeping the downstream pressure constant as the press cycles.
Regulate the air feeding several workstations on a conveyor line, so each station sees the same pressure regardless of upstream swings.
Hold a precise pressure for a large-bore clamping actuator on a welding fixture, where a steady force is critical for part alignment.
Choose the GAR600 when the line needs a 1in port and the mass of a 1390 g body to feed a machine header or a multi-station circuit. The standard S type regulates from 0.05-0.9 MPa (7-130 psi), which covers most industrial actuators and tools; the lower L type would cap at 0.4 MPa and cannot reach a 0.5-0.6 MPa setpoint. This unit has no gauge, so read the pressure on the line's own panel gauge, and the included bracket supports the heavy body on a panel or frame. The PT thread reads MPa/psi on any fitted gauge, and the K option adds a reflux valve. If the air also needs cleaning, use a GAFR600-25 or a separate GAF filter upstream. The S type's adjustable band is about 2.4x the L type's span (0.85 MPa vs 0.35 MPa), giving you a wider operating window.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR600-25 filter-regulator as your air-prep needs grow.
The GAR60025SNK is a regulator-only unit with a 1in port and a weight of 1390 g. It regulates from 0.05-0.9 MPa (7-130 psi) with a max supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The operating temperature range is -20 to 70 C. It has no gauge, includes a mounting bracket, uses PT threads, and has a reflux valve attached.
The N in the code means no gauge is fitted, so you read the downstream pressure on the line's own panel gauge instead. The K option means a reverse-flow (reflux) valve is attached to the unit. This valve is included per the model code, but its specific function is not detailed in our data.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.