verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-10 FRL Unit (GC30010LF1W)

The AirTAC AirTAC GC300-10 FRL Unit (GC30010LF1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.68 $93.54Save 6% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-10 FRL Unit (GC30010LF1W)

GC30010LF1W is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This configuration is size 300 with PT3/8 ports (PT thread as standard), the low-pressure regulator type, a differential-pressure drain on the filter bowl, a 5 um fine-filtration element (the W grade, finer than the 40 um standard) and an embedded square gauge reading in MPa. The set removes water and fine particulate, holds a steady downstream pressure (adjustable 0.15-0.9 MPa / 20-130 psi on the differential-pressure drain version) and meters oil mist into the line. Maximum working pressure is 1.0 MPa (145 psi), operating temperature is -5 to 70 C (non-freezing), and the 300-size bowls are polycarbonate (PC).

This is a catalogue AirTAC part, available across the G-series in sizes 200, 300, 400 and 600 with 40 um standard or 5 um (W) filtration, differential-pressure, automatic or manual drains, square or round gauges, and PT, G (BSPP) or NPT thread options. Flow is published as curves rather than a single rating, so we confirm flow and other datasheet figures on request before you order.

AirTAC GC300-10 FRL Unit (GC30010LF1W) Technical Specifications

ModelAirTAC GC300-10 FRL Unit (GC30010LF1W)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-10 FRL Unit (GC30010LF1W)

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-10 FRL Unit (GC30010LF1W) Is Used

cable

Wire and cable processing machinery

Conditions air for the pneumatic tensioners, cutters and capstan brakes on wire drawing and spooling lines, where the 5 um element guards fine pilot valves along fast-cycling circuits.

view_module

Electronic component handling lines

Feeds vacuum ejectors, slide cylinders and gentle-grip actuators on PCB and component transport modules, supplying clean 5 um air at a steady regulated pressure with oil mist for the moving parts.

engineering

Test bench pneumatic circuits

Serves engineering test rigs that stroke test cylinders and valves repeatedly, combining fine filtration, a fixed set pressure read on the square gauge and lubrication for long bench life.

Is the AirTAC GC300-10 FRL Unit (GC30010LF1W) the Right Station?

Size 300 with PT3/8 ports is the mid-range step in the G-series; move to 200, 400 or 600 as your branch line and flow demand require. Here W selects the 5 um element over the standard 40 um grade - the right choice when sensitive pilot valves or precision actuators sit downstream. The F code gives the embedded square MPa gauge; the external round gauge is the alternative code.

The filter bowl carries the differential-pressure drain (default), with automatic (A) and manual (M) available as codes. This set uses the low-pressure regulator type (L). PT thread is standard, with G (BSPP) and NPT available to order, and a mounting bracket can be specified. AirTAC publishes flow as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

AirTAC GC300-10 FRL Unit (GC30010LF1W) FAQ

Yes - on request. AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not print a number here. Send us your line pressure and the air consumption of the circuit and we will confirm the flow from the datasheet and check that size 300 with PT3/8 fits the duty before you order.

W selects the 5 um fine-filtration element instead of the standard 40 um grade, and F selects the embedded square gauge with an MPa scale instead of the external round gauge. The remainder is fixed by the code: three-unit filter-regulator-lubricator set, size 300, PT3/8, low-pressure regulator type and differential-pressure drain on the filter bowl.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-10 FRL Unit (GC30010LF1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30010LF1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.