verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015ALF1W)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015ALF1W) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$98.12 $104.24Save 5% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015ALF1W)

GC30015ALF1W is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator built as one 300-size station for compressed air only. The 1/2 in PT port suits a main drop feeding several downstream circuits. The automatic drain opens the filter bowl as condensate collects, the 5 um (W) element gives finer particulate removal than the standard 40 um element, and the low-pressure (L) regulator type is set up for circuits running below standard line pressure. An embedded square gauge on an MPa scale shows the regulated downstream pressure, and the lubricator meters oil mist into the air stream.

The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, available as single units, two-unit sets or three-unit combinations in PT, G (BSPP) or NPT threads. On this 300 size the bowls are PC (polycarbonate), operating temperature is -5 to 70 C (non-freezing) and maximum working pressure is 1.0 MPa (145 psi). Flow is published as curves rather than a single rated figure, so ask us to confirm datasheet and sizing figures for your application on request.

AirTAC GC300-15 FRL Unit (GC30015ALF1W) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015ALF1W)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015ALF1W)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015ALF1W) Is Used

science

Lab automation actuator feed

Conditioning air to grippers and lift cylinders on laboratory automation, where the 5 um element limits particulates reaching sensitive motion components.

handyman

Screen printing machine air

Feeding squeegee and clamp cylinders on a screen printing press with filtered, regulated and lubricated air; the finer element supports consistent print quality.

tune

Bottling line fill-head supply

Regulating and lubricating the air to fill-head and capping actuators on a bottling line, with automatic draining keeping condensate out of the circuit during wet, humid runs.

Is the AirTAC GC300-15 FRL Unit (GC30015ALF1W) the Right Station?

This configuration gives you a 300-size F.R.L. with a 1/2 in PT port, automatic drain, 5 um element and an embedded square MPa-scale gauge. If your application does not need fine filtration, the standard 40 um element (GC30015ALF1) is the same set without the W suffix. The drain can be ordered as manual (M) or differential-pressure (blank) instead of automatic (A), the gauge as an external round type with psi or bar scale, and the thread as G (BSPP) or NPT instead of the standard PT. Because this is the L (low-pressure) type, confirm the exact adjustment range for your set pressure with us before ordering. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015ALF1W) FAQ

Yes. AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no single number to print here. Send us your application details and we will confirm the curve and datasheet figures for this exact model on request.

Both deliver filtered, regulated and lubricated air. The GC combines a separate filter, regulator and lubricator as three units, while the GFC pairs a filter-regulator with a lubricator in two. Choose based on the mounting space and service arrangement you want; we can confirm the best fit on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015ALF1W)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015ALF1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.