The AirTAC AirTAC GC300-15 FRL Unit (GC30015ALN) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC30015ALN is a genuine AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator, each installed as its own module in the line. This 300-size set is supplied with a PT1/2 port, an automatic drain on the filter bowl, the standard 40 um filter element and no pressure gauge (N). The L suffix marks the low-pressure type, intended for circuits that run below standard line pressure. All bowls are polycarbonate at this size, the medium is compressed air, and the set works from -5 to 70 C (non-freezing). Max working pressure is 1.0 MPa (145 psi).
AirTAC builds the GC series in 200, 300, 400 and 600 sizes with 1/8 in through 1 in ports, a choice of G (BSPP) or NPT threads as catalogue options, automatic, manual or differential-pressure drains, 5 um (W) or 40 um filtration, and gauge variants. Flow for the GC series is published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request.
| Model | AirTAC GC300-15 FRL Unit (GC30015ALN) |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-15 |
| Build order | Filter → regulator → lubricator |
Filtering, regulating and oil-mist lubricating the air feed to spray guns on a furniture-finishing line that runs its atomisation circuit below standard plant pressure.
Supplying conditioned air to pallet-clamp cylinders on a CNC machining centre, where the low-pressure type regulator suits the clamp circuit's reduced setting.
Conditioning the compressed-air supply to a lab test rig that needs filtered, regulated and lubricated air at reduced pressure with unattended condensate drainage.
Start with the port step: this 300-size set carries a 1/2 in port, and the next sizes up (400, 600) offer larger ports and more flow if your demand grows. The automatic drain ejects condensate on its own, which suits unattended installation; manual and differential-pressure drain variants exist in the series. The standard 40 um element covers general plant air; specify the W (5 um) version where finer filtration is needed. Thread is PT as standard - order the G (BSPP) or NPT option if your piping uses those.
Flow through the GC series is published as curves, not a single rated figure, so we do not quote a number here. Send us your line pressure, downstream demand and port size and we will confirm the datasheet figures and check the sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.
AirTAC publishes GC-series flow as curves, not a single rated figure, so we do not quote a number on this page. Send us your line pressure, downstream demand and port size, and we will confirm the datasheet figures and check the sizing against your application before you order.
The A suffix means the filter bowl drains condensate automatically, without operator intervention - useful for unattended lines. The GC series is also available with manual or differential-pressure drains; ask us if you prefer one of those for this application.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.