verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-15 FRL Unit (GC30015ALNW)

The AirTAC AirTAC GC300-15 FRL Unit (GC30015ALNW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$92.47 $98.45Save 6% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC300-15 FRL Unit (GC30015ALNW)

GC30015ALNW is a genuine AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator, each installed as its own module in the line. This 300-size set is supplied with a PT1/2 port, an automatic drain on the filter bowl, the finer 5 um (W) filter element and no pressure gauge (N). The L suffix marks the low-pressure type, intended for circuits that run below standard line pressure. All bowls are polycarbonate at this size, the medium is compressed air, and the set works from -5 to 70 C (non-freezing). Max working pressure is 1.0 MPa (145 psi).

AirTAC builds the GC series in 200, 300, 400 and 600 sizes with 1/8 in through 1 in ports, a choice of G (BSPP) or NPT threads as catalogue options, automatic, manual or differential-pressure drains, 5 um (W) or 40 um filtration, and gauge variants. Flow for the GC series is published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request.

AirTAC GC300-15 FRL Unit (GC30015ALNW) Technical Specifications

ModelAirTAC GC300-15 FRL Unit (GC30015ALNW)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-15 FRL Unit (GC30015ALNW)

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-15 FRL Unit (GC30015ALNW) Is Used

air

Pilot-air feed on a cartoning machine

Supplying 5 um filtered, regulated and lubricated air to pilot valves on a cartoning machine, keeping fine particulate out of the control circuit.

factory

Thermoformer valve train

Conditioning air for sealing and cut-off cylinders on a thermoforming packaging line, where the 5 um element protects the downstream valve train.

settings_input_component

Process-skid control panel

Feeding lubricated, low-pressure regulated air to small actuators and solenoid blocks on a process-skid control panel with finer-than-standard filtration.

Is the AirTAC GC300-15 FRL Unit (GC30015ALNW) the Right Station?

The 5 um (W) element is the key choice here: it filters more finely than the 40 um standard element, which suits control valves and pilot circuits that dislike fine particulate. The 300-size 1/2 in port sets the flow path; step up to 400 or 600 if your demand needs a larger port. The automatic drain handles condensate without attention, and manual or differential-pressure drain variants exist in the series. Thread is PT as standard - order G (BSPP) or NPT if your piping differs.

Flow through the GC series is published as curves, not a single rated figure, so we do not quote a number here. Send us your line pressure, downstream demand and port size and we will confirm the datasheet figures and check the sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

AirTAC GC300-15 FRL Unit (GC30015ALNW) FAQ

AirTAC publishes GC-series flow as curves, not a single rated figure, so we do not quote a number on this page. Send us your line pressure, downstream demand and port size, and we will confirm the datasheet figures and check the sizing against your application before you order.

The standard GC filter element is 40 um; the W suffix in this code selects the 5 um element, which removes finer particulate. Choose W for pilot valves, control circuits and other sensitive downstream equipment, and standard 40 um for general plant air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC300-15 FRL Unit (GC30015ALNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015ALNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.