verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-10 FRL Unit (GC40010LNW)

The AirTAC AirTAC GC400-10 FRL Unit (GC40010LNW) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$118.35 $124.97Save 5% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-10 FRL Unit (GC40010LNW)

The GC40010LNW is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator working together on one compressed-air line. This size 400 unit carries a 3/8 in PT port. The W code selects the finer 5 um filtering element, the filter bowl drains by differential pressure, no gauge is fitted, and the L code makes this the low-pressure regulator type for circuits that are set well below full line pressure. Maximum inlet pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G-series F.R.L. spans sizes 200 to 600 with ports from 1/8 in to 1 in, and options across the series include manual or automatic drain, a 40 um or 5 um element, embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing and the datasheet for this configuration before you order.

AirTAC GC400-10 FRL Unit (GC40010LNW) Technical Specifications

ModelAirTAC GC400-10 FRL Unit (GC40010LNW)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-10 FRL Unit (GC40010LNW)

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-10 FRL Unit (GC40010LNW) Is Used

factory

Robot weld-cell air prep

Feeding a welding robot's gripper and clamping cylinders with filtered, regulated, oil-misted air at a low set pressure, with the 5 um element protecting the valve stack from fine particulate.

tune

Paint-line spray gun supply

Conditioning the atomizing air to manual spray guns on a finishing line: water and 5 um-grade debris removed, pressure set low and steady, and a controlled oil mist carried to the gun trigger and needle.

conveyor_belt

Conveyor stopping cylinders

Supplying the pneumatic stopper and pusher cylinders along a packaging conveyor, where low regulated pressure is enough for gentle product handling and the lubricator keeps cylinder seals running smoothly.

Is the AirTAC GC400-10 FRL Unit (GC40010LNW) the Right Station?

Size 400 with its 3/8 in port sits mid-range in the G-series; step to 600 or down to 300 if the flow curve for your line points elsewhere. The L-type low-pressure regulator is the right choice when set pressures stay low - confirm its exact adjustment ceiling with us from the datasheet. The differential-pressure drain on this unit opens in response to the pressure drop across the element; manual (M) or automatic (A) drain variants are orderable. The 5 um element suits lines where finer debris must be caught, while 40 um is the standard grade. Thread is PT as the standard, with G and NPT as orderable options, and a bracket can be specified. Because flow is published as curves, not a single rated figure, send us your application and we will confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

AirTAC GC400-10 FRL Unit (GC40010LNW) FAQ

AirTAC publishes G-series flow as curves rather than one rated figure, and the low-pressure L type has its own curve. Send us your line pressure and air demand and we will confirm the correct size from the datasheet before you order.

The N code in the model leaves the pressure gauge off. Gauge-equipped variants of the size 400 GC series can be ordered instead, with an embedded square gauge or an external round gauge in MPa, psi or bar scales - ask us to quote the variant you need.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-10 FRL Unit (GC40010LNW)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.