verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type

The AirTAC AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$125.01 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type

The AirTAC GC400 series is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This GC400-15G is built on the size 400 body with a G1/2 (BSPP) port. It is the low-pressure regulator type, fitted with a 5 um filter element (code W), a differential-pressure drain on the filter bowl, a round pressure gauge scaled in psi, and a mounting bracket. The bowls are polycarbonate (PC) and no reverse/check valve is fitted.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600, with port sizes from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um (W) filtration, gauge scales in MPa, psi or bar, and PT, G or NPT thread. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type Technical Specifications

ModelAirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type Is Used

factory

Packaging line air supply

Feeding filtered, regulated and lubricated air to the wrapper, case sealer and cylinder-driven clamp units on a carton packaging line, with the 5 um element protecting downstream valves from fine dust.

conveyor_belt

Conveyor actuator supply

Conditioning the air that drives stopper, pusher and lift cylinders along a bottling or sorting conveyor, with the regulator holding the line's set pressure and the lubricator metering oil mist to the actuators.

build

Assembly tool air drop

Serving a pneumatic tool drop at an assembly or maintenance bench, where the filter removes water and chips, the regulator keeps a steady set pressure and the lubricator keeps impact wrenches and riveters oiled.

Is the AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type the Right Station?

Size 400 with a G1/2 port suits lines that draw a substantial air volume; step up or down through sizes 200-600 as demand changes. Because flow is published only as curves, not a single rated figure, ask us to confirm sizing against your application before ordering. The 5 um element (code W) gives finer particulate removal than the 40 um standard grade. Drain is differential-pressure here; automatic (A) and manual (M) drains are available in the same family. The round gauge is scaled in psi; the embedded square gauge and MPa or bar scales are the other catalogue options. Thread is G (BSPP) as decoded; PT is the standard thread and NPT is an order option. The low-pressure type (code L) is the variant for lower working pressures; its exact adjustment range is not published, so confirm it with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number here. Send us your application details and we will confirm the flow and sizing from the datasheet before you order.

The W in this code specifies the 5 um element, which removes finer particulate than the 40 um standard grade. The GC family is also available with the standard 40 um element if your line does not need the finer filtration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC400-15G F.R.L. Unit, G1/2, Low-Pressure Type

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.