verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600C20LC2WG F.R.L. Combination, G3/4

The AirTAC AirTAC GC600C20LC2WG F.R.L. Combination, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.13 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC600C20LC2WG F.R.L. Combination, G3/4

The AirTAC GC600C20LC2WG is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single supply point. The filter stage removes water and particulate down to 5 um (the fine W grade rather than the standard 40 um element), the low-pressure-type regulator sets downstream pressure, and the lubricator meters oil mist into the air line. This size-600 unit is built for a 3/4 in port with G (BSPP) thread, ships with a differential-pressure drain on the filter bowl, an external round gauge reading in psi, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC600 series is the largest size in the G-series line, with 200, 300, 400 and 600 sizes available, and options across the family for drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT to order) and bracket choice. At this 600 size the filter and lubricator bowls are aluminium alloy. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

AirTAC GC600C20LC2WG F.R.L. Combination, G3/4 Technical Specifications

ModelAirTAC GC600C20LC2WG F.R.L. Combination, G3/4
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600C20LC2WG F.R.L. Combination, G3/4

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the AirTAC GC600C20LC2WG F.R.L. Combination, G3/4 Is Used

factory

Automotive paint line air drops

Conditions the shop air at the line drop that feeds spray guns and air-assisted applicators: fine 5 um filtration for finish quality, regulated low-pressure supply to the guns, and oil mist to keep gun spindles and air motors running smoothly.

precision_manufacturing

CNC machining cell supply

Sits at the inlet of a machining cell to clean, regulate and lubricate the air serving pallet clamps, tool-change cylinders and air-powered fixtures, with the round psi gauge giving operators a local pressure reference at the cell.

conveyor_belt

Cartoning and packaging line actuators

Prepares the air feeding conveyor diverters, pusher cylinders and case-erector actuators on a packaging line: water and 5 um particulate removal ahead of the valves, a set regulated supply, and lubrication for the cylinders doing continuous high-cycle work.

Is the AirTAC GC600C20LC2WG F.R.L. Combination, G3/4 the Right Station?

Choose the 600 size with its 3/4 in port when your supply line and expected air demand sit at the top of the G-series range; smaller 200/300/400 sizes step down in port and flow capacity, and we will confirm the flow curve against your demand before you order. This configuration carries the 5 um W-grade element - select it where downstream valves, cylinders or instruments need finer filtration than the standard 40 um. The low-pressure-type regulator is intended where working pressures sit below the standard regulator band; its exact adjustment range is not published in the catalogue, so confirm it with us for your setpoint. The differential-pressure drain bleeds the bowl automatically as pressure drops across the element - choose a manual-drain or automatic-drain variant instead if your duty cycle or access needs differ. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue choices. G thread is specified here; PT is the standard thread and NPT is also available to order. A mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

AirTAC GC600C20LC2WG F.R.L. Combination, G3/4 FAQ

AirTAC publishes flow for the GC600 series as curves rather than a single rated figure, so there is no one rated flow number we can quote. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the flow curve from the datasheet and check the sizing for you before you order.

The L in the code marks the low-pressure-type regulator, intended for circuits whose working pressure sits below the standard regulator band; the catalogue does not publish its exact adjustment range, so confirm your setpoint with us. The C2 marks a fitted external round gauge reading in psi - the embedded square gauge is the standard fitting, and MPa or bar scales are alternative catalogue choices.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC600C20LC2WG F.R.L. Combination, G3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20LC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.