verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4

The AirTAC AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.74 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4

The AirTAC GC600C20MLC2 is a three-unit F.R.L. combination that brings together a separate air filter, a pressure regulator and an oil-mist lubricator, so one assembly cleans the compressed air, holds the working pressure steady and adds lubricating mist for downstream tools and cylinders. This 600-size unit is built around a 3/4 in PT port, uses the standard 40 um filter element, and is fitted with a manual drain on the filter bowl. The regulator is the low-pressure type, and the round pressure gauge supplied with this code reads in psi. At size 600 the filter bowls are aluminium alloy rather than polycarbonate, and a mounting bracket is included.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 5 um filter element option, gauge scale choices, and G or NPT thread variants to order. Flow is published in the AirTAC catalogue as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4 Technical Specifications

ModelAirTAC GC600C20MLC2 F.R.L. Combination, PT3/4
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4 Is Used

factory

Automotive paint and finishing line

A body shop's spray-booth supply run needs air that is free of water and particulate, held at a stable low working pressure for the atomising regulators, and lightly oiled where the plant still runs lubricated spray guns and air motors. A three-unit F.R.L. at the booth inlet does all three jobs in one assembly, and the 3/4 in port matches the branch feeding several booths.

precision_manufacturing

Stamping press pneumatic counterbalance circuits

Mechanical stamping presses and coil-feed lines run cylinders and air counters that need clean, moisture-free air at a steady set pressure, plus mist lubrication for the valves and cylinders on older equipment. A GC combination mounted at the press drop, with the bracket on the machine frame, keeps the whole circuit supplied from one service point.

settings_input_component

Bottling and packaging machine air supply

Packaging machines with pneumatic actuators, grippers and glue-head cylinders draw from a shared 3/4 in header. A filter-regulator-lubricator set at each machine's take-off removes water carried over from the compressor room, sets the machine's working pressure with the psi gauge visible to the operator, and mists the cylinders and valves that are specified for lubricated air.

Is the AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4 the Right Station?

Start with the port and size: this code is the 600 size on a 3/4 in PT port, the largest step in the GC range, so choose it when the line's required flow points to the top of the series - we will confirm the exact flow from the catalogue curves before you order. The filter here is the standard 40 um grade; if the application needs finer filtration, the 5 um (W) element is the option to ask about. Drain choice matters: this unit has a manual drain, which suits attended installations where an operator can bleed the bowl, while automatic and differential-pressure drains suit unattended lines. The regulator in this code is the low-pressure type, intended for circuits that work below the standard regulator band - its exact adjustment range is not published in the catalogue, so confirm it with us. The gauge fitted reads in psi; MPa and bar scales are the other options. Thread is PT as standard, with G (BSPP) and NPT available as order options, and a mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4 FAQ

AirTAC publishes flow for the GC series as curves in the catalogue, not as a single rated number, so we do not quote a rated flow figure for this unit. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing against the datasheet curves on request before you order.

The M in this code specifies a manual drain on the filter bowl: condensate collects in the bowl and an operator opens the drain to release it, which suits installations that are checked regularly. If the unit will sit on an unattended line, ask about the automatic (A) or differential-pressure (standard, blank) drain variants instead. Note that the regulator adjustment range differs by drain type on the standard regulator; this code is the low-pressure type, and we confirm its exact range on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC600C20MLC2 F.R.L. Combination, PT3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C20MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.