The AirTAC AirTAC GC600C25LC2 F.R.L. Combination Unit, PT1 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC600C25LC2 is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one air-treatment set for a compressed-air line. This configuration is the 600 size with a 1 in PT port, the largest step in the G-series range. The filter element is the standard 40 um grade and the bowl uses a differential-pressure drain, while the regulator is the low-pressure type and is supplied with an external round gauge scaled in psi. Because the size-600 bowls are aluminium alloy, the filter and lubricator bowls on this unit are metal rather than polycarbonate, and a mounting bracket is included.
This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, a choice of PT, G or NPT thread, differential-pressure, automatic or manual drains, a 40 um or 5 um filter grade, and gauge scale options in MPa, psi or bar. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | AirTAC GC600C25LC2 F.R.L. Combination Unit, PT1 Port |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · See datasheet · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-C2 |
| Build order | Filter → regulator → lubricator |
Installed at the head of a 1 in ring main feeding a factory floor, this three-unit set cleans water and particulate from the compressed air, holds the line at the pressure the downstream stations were set up for, and carries oil mist to keep air tools and cylinders lubricated.
On a bottling or carton-packing conveyor driven by pneumatic actuators, this combination conditions the supply in one assembly: the filter removes condensate and debris, the low-pressure regulator holds a gentle working pressure for delicate clamping, and the lubricator mists oil into the actuator air.
Fitted at the air inlet of a machining centre or press, the set protects the machine's valves and cylinders: the 40 um filter stops scale and pipe debris, the regulator keeps clamp and counterbalance circuits at their set pressure, and the lubricator feeds the air motors and cylinders.
Start from the port and size: this unit steps up to the 600 frame with a 1 in PT connection, which suits lines where a smaller frame would restrict the circuit - match the frame against the flow your line needs rather than the pipe alone. The differential-pressure drain on the filter bowl is the standard choice and needs no operator attention, but automatic or manual drains can be ordered if your maintenance routine prefers them. The 40 um element is the standard grade; a 5 um element (code W) is available where finer particulate removal is required. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the alternatives. PT thread is the standard here, with G and NPT available as order options, and the mounting bracket is included. Note that this is the low-pressure regulator type, so have us confirm the exact adjustment range and the flow curves from the datasheet against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.
AirTAC publishes flow for the G-series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment and we will confirm the flow from the datasheet curves for this 600-size unit before you order.
The L in the code marks the low-pressure regulator variant, intended for circuits that run at lower working pressures than the standard setting range covers; the exact adjustment range for this type is not published in the summary sheet, so we confirm it on request. The fitted round gauge on this unit reads outlet pressure in psi, and MPa or bar scales are available as alternatives.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.