verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um

The AirTAC AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$200.70 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um

The AirTAC GC600C25MF2W is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembled set: a separate filter, a separate pressure regulator and a separate oil-mist lubricator. This size 600 configuration has PT1 (1 in) ports, a manual drain on the filter bowl, a fine 5 um filter element (the 40 um standard element is available as the non-W variant), an embedded square gauge reading in psi, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). At size 600 the filter and lubricator bowls are aluminium alloy, and the unit is rated to 1.0 MPa (145 psi) maximum inlet pressure with an operating temperature range of -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with automatic, manual or differential-pressure drains, 40 um or 5 um filtration, G (BSPP) or NPT threads in place of the PT standard, different gauge scales, and a reverse/check valve. Flow figures for this series are published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um Technical Specifications

ModelAirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um

GC600G-series F.R.L. combination, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-C2 filter, GR600-C2 regulator and GL600-C2 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · See datasheet · 40 µm
One size downGC400
Two-unit equivalentGFC600-C2
Build orderFilter → regulator → lubricator

Where the AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um Is Used

factory

Automotive paint line air supply

Feeding clean, regulated and lubricated air to the spray pumps, bell applicators and transfer actuators on an automotive paint line, where oil misting and fine filtration protect finish quality.

conveyor_belt

Bottling line conveyor and filler actuators

Conditioning the air supply to pneumatic cylinders, grippers and stopper gates on a bottling or canning conveyor, keeping moisture and particles out of high-cycle actuators running through long shifts.

precision_manufacturing

CNC machining centre clamping circuits

Supplying filtered, pressure-regulated and lubricated air to the clamping fixtures, tool-change cylinders and chip-ejection jets of a CNC machining centre, where stable regulated pressure keeps workholding consistent.

Is the AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um the Right Station?

Start with the port and size step: this unit is size 600 with a 1 in PT port, the largest step in the GC range, so match it against the air demand of the machine or line it will feed - and because flow is published only as curves, ask us to confirm sizing against your application before ordering rather than assuming from the port alone. Choose the drain type where it applies: this configuration has a manual drain, which suits positions someone walks past on a routine; automatic or differential-pressure drains suit inaccessible or unattended installations. This unit carries the 5 um element (code W) instead of the 40 um standard - pick 5 um where downstream equipment needs finer particulate removal, 40 um for general protection. The square gauge here reads in psi; MPa and bar scales are orderable. Thread is PT as standard, with G (BSPP) and NPT as catalogue options, and a mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-C2 regulator with a GF600-C2 filter on that branch.

AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um FAQ

AirTAC publishes flow for the GC series as performance curves, not as a single rated figure, so we do not quote a rated flow number. Tell us your operating pressure and the air demand of the equipment you are feeding, and we will confirm the flow figures from the datasheet for this exact configuration before you order.

The M in the code GC600C25MF2W specifies a manual drain on the filter bowl: condensate is released by hand, which suits installations checked on a regular routine. If the unit will sit in an inaccessible or unattended position, the same size 600, 1 in configuration can be ordered with an automatic drain (code A) or the differential-pressure drain that is the series default, and the filter grade can be the 40 um standard element instead of the 5 um element fitted here.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GC600C25MF2W F.R.L. Unit 1 in PT, Manual Drain, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC600C25MF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.