The AirTAC AirTAC GFR20006MJF1WT Filter Regulator NPT1/8 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR20006MJF1WT is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This 200-size unit has a 1/8 in NPT port, a polycarbonate bowl with manual drain, and a 5 um filter element - the finer of the two available grades. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), the maximum inlet pressure is 1.0 MPa (145 psi), and the embedded square gauge is scaled in MPa. No mounting bracket is included with this suffix.
GFR200 is the smallest size in the AirTAC G-series filter-regulator line (200/300/400/600), each configurable with your choice of drain type, filter grade, gauge and thread (PT is the standard; G and NPT are catalogue options to order). This is a genuine AirTAC part. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | AirTAC GFR20006MJF1WT Filter Regulator NPT1/8 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | PT1/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · PT1/8" · 5 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-06 (two-unit set) |
Clean, regulated air feeding the solenoid-valve manifold that pilots the seal, cut and reject cylinders on a horizontal form-fill-seal packaging machine.
Point-of-use air preparation for the pneumatic stoppers, pushers and gating cylinders that divert cartons between lanes on a distribution conveyor line.
Filtered, pressure-controlled supply for the small air cylinders and grippers in an automated sample-handling or vial-capping station, where the 5 um element protects fine components.
Choose the 200 size with its 1/8 in port when your line volume and fittings are at the small end of the G-series range; step up to 300/400/600 for larger ports and higher flow duty. This unit is already specified with the 5 um element (the W option) instead of the 40 um standard - pick 5 um where downstream components need finer filtration, 40 um for general water and particulate removal. The manual drain means an operator opens the bowl drain during checks; if you prefer automatic or differential-pressure draining, those are separate suffixes in the same series. The square gauge here reads in MPa; psi or bar scales and an external round gauge are orderable alternatives. Thread is NPT on this code; PT is standard and G (BSPP) is also available. No bracket is fitted with the J suffix - add a bracketed variant if you need panel or surface mounting.
Before ordering, have us confirm sizing: flow is published as curves, not a single rating, so we will check the datasheet against your air consumption and line pressure.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and air consumption and we will confirm the datasheet flow curve and check the 200 size against your application before you order.
The M in the code specifies a manual drain: accumulated condensate is released by hand during routine checks. The GFR200 series is also available with automatic or differential-pressure drains under different suffixes, so you can switch if unsupervised draining suits your installation better.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.