verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain

The AirTAC AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$41.27 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain

The AirTAC GFR30008MF2T is a GFR300 series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a 1/4 in NPT port, a manual-drain polycarbonate bowl, a 40 um standard filter element, and an embedded square gauge reading in psi. Maximum inlet pressure is 1.0 MPa (145 psi), the regulated output range is 0.05-0.9 MPa (7-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.

This is a genuine AirTAC part. The GFR family is made in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, PT as the standard thread and G or NPT as order options, plus a choice of manual, automatic or differential-pressure drains, 40 um or 5 um (code W) filtration, square or round gauges with MPa, psi or bar scales, and an optional reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain Technical Specifications

ModelAirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain
SeriesGFR300 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain Is Used

factory

Packaging-line actuators

Feeds filtered, regulated air to carton-sealing and case-erector cylinders on a packaging line, with the manual drain emptied during scheduled stops.

conveyor_belt

Sorting-conveyor diverters

Supplies clean air at a set pressure to diverter-gate cylinders on a sorting conveyor, keeping gate actuation consistent along the line.

science

Pneumatic test benches

Provides a filtered, manually adjustable regulated supply for bench-top pneumatic test rigs where the operator sets and reads pressure in psi.

Is the AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain the Right Unit?

The real, decodable choices are: the size and port step (200/300/400/600, ports 1/8 to 1 in), matched to the air demand of your line; the drain type (manual here, with automatic and differential-pressure available in the family); the filter grade (40 um standard, 5 um with code W); the gauge and its scale (this unit: embedded square, psi); the thread (PT standard, G or NPT to order); and whether a mounting bracket is required. Flow is published as curves, not a single rated figure, so please ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Ask us and we will confirm the datasheet flow curves against your application's air demand before you order.

The M in the code means the polycarbonate bowl is drained by hand, which suits lines with regular maintenance stops. The GFR family also offers automatic (code A) and differential-pressure (blank) drains, and the manual-drain version has the wider 0.05-0.9 MPa (7-130 psi) regulation range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR300-08 Filter Regulator, NPT 1/4 in, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008MF2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.