verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

AirTAC GFR600-25 Filter Regulator, 1 in NPT

The AirTAC AirTAC GFR600-25 Filter Regulator, 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$118.14 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR600-25 Filter Regulator, 1 in NPT

The AirTAC GFR600-25 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is the size 600 unit with a 1 in NPT port, the standard 40 um filter element, a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element rises, and a round pressure gauge reading in bar. A reverse/check valve is fitted, and no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The size 600 bowl is aluminium alloy.

This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options include a 5 um element (code W), automatic or manual drain, square embedded or external round gauges with MPa, psi or bar scales, G (BSPP) or NPT threads in place of the PT standard, and bracket choices. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

AirTAC GFR600-25 Filter Regulator, 1 in NPT Technical Specifications

ModelAirTAC GFR600-25 Filter Regulator, 1 in NPT
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR600-25 Filter Regulator, 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the AirTAC GFR600-25 Filter Regulator, 1 in NPT Is Used

factory

Pneumatic press air supply

Conditioning and regulating the compressed air feeding a stamping or forming press: the 40 um element strips water and pipe scale from the main line, the regulator holds a steady setting to the press cylinders, and the 1 in NPT port matches the plant's main drop on heavy-duty machines.

conveyor_belt

Bottling line conveyor actuation

Feeding clean, regulated air to the cylinder banks that index, clamp and divert bottles on a filling or packaging conveyor, where the differential-pressure drain keeps condensate out of the valves without an operator bleeding the bowl each shift.

valve

Directional valve manifold supply

Mounted upstream of a directional control valve manifold on a machine frame, so each valve station receives filtered air at a fixed regulated pressure, with the bar gauge giving operators a local reading of the set point at the manifold.

Is the AirTAC GFR600-25 Filter Regulator, 1 in NPT the Right Unit?

Start with the port and size step: GFR units step through sizes 200, 300, 400 and 600, and the size 600 with a 1 in port suits the largest branch lines, so match the step to the air demand of the line it feeds. Then choose the drain: differential-pressure (this unit) vents condensate on pressure drop, automatic drains continuously, and manual drain requires an operator to bleed the bowl - pick based on how often the installation is attended. Choose the 40 um standard element for general air preparation or the 5 um W option for finer protection; choose the gauge type and scale (square embedded or external round, in MPa, psi or bar - this unit carries an external round gauge in bar). Thread is PT as standard, with G (BSPP) and NPT as order options - this unit is NPT. Bracket is optional (this unit has none), and a reverse/check valve can be fitted (it is on this unit). Because flow is published as curves and not a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

AirTAC GFR600-25 Filter Regulator, 1 in NPT FAQ

AirTAC publishes GFR flow performance as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing against the datasheet curves on request before you order.

The differential-pressure drain on this GFR600-25 bleeds collected condensate from the bowl automatically whenever the pressure drop across the 40 um element rises, with no operator involvement. Automatic drain is the choice where you want continuous draining regardless of load, and manual drain suits installations that are checked regularly. Note that the regulation range differs by drain type: with the differential-pressure drain fitted here it is 0.15-0.9 MPa (20-130 psi), while manual-drain versions adjust from 0.05-0.9 MPa (7-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR600-25 Filter Regulator, 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025JC3TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.