verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um

The AirTAC AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.43 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um

The AirTAC GFR600C20F2WGK is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in one body. This 600-size unit is threaded G3/4 (G thread), carries a 5 um filter element (the finer W grade; 40 um is the standard), drains by differential pressure, and is fitted with an embedded square gauge reading in psi plus a reverse/check valve. The standard regulator covers 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi). At size 600 the bowl is aluminium alloy, and the unit operates from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options for manual or automatic drains, 40 um or 5 um elements, gauge scale in MPa, psi or bar, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um Technical Specifications

ModelAirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um Is Used

precision_manufacturing

CNC machining centre air supply

Filtered and regulated air feeding the tool-change cylinders and pneumatic clamps on a machining centre, with the 5 um element protecting downstream valves from fine particulate.

conveyor_belt

Packaging line stopper and pusher cylinders

Steady regulated pressure for the stop, divert and push cylinders along a carton packaging conveyor, with the check valve holding the set pressure against upstream dips.

factory

Automotive paint shop spray air

Point-of-use filtration and regulation ahead of spray guns in a paint booth, where the 5 um element and a stable set pressure support a consistent finish.

Is the AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um the Right Unit?

Choose the size by port and demand: the 200 to 600 step runs from 1/8 to 1 inch, and this 600 unit sits at the 3/4 inch G thread. Decide the drain: differential-pressure (this model), automatic (A) or manual (M). Pick the element: 40 um standard or 5 um with the W code, as fitted here. Select the gauge scale (MPa, psi or bar) and whether to add a reverse/check valve (K). PT is the standard thread; G and NPT are order options. Flow is published as curves, not a single rating, so have us confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um FAQ

AirTAC publishes GFR600 flow as curves rather than a single rated figure, so we do not quote one number. Send us your application details and we will confirm the flow and the full datasheet figures on request.

The W code in the model specifies the 5 um grade, which captures finer particulate than the 40 um standard element. If your line does not need the finer grade, the 40 um version of the same unit is available to order.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR600C20F2WGK Filter Regulator G3/4 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20F2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.