The AirTAC AirTAC GR200-06 Pressure Regulator (GR20006F2) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The AirTAC GR series is a dedicated air pressure regulator for compressed air only: it reduces and holds downstream pressure and contains no filter, no drain bowl and no lubricator. This GR20006F2 is the 200 size with a 1/8 in PT port and an embedded square gauge scaled in psi, the reading most US technicians and drawings expect. Adjustment range is 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -20 to 70 C (non-freezing).
This is a genuine AirTAC part. The GR family spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, PT standard thread plus G (BSPP) and NPT options, round or square gauges in MPa, psi or bar scales, a low-pressure type limited to 0.4 MPa, and bracket or panel mounting. Flow is published as curves rather than a single rated figure, so we will confirm the datasheet flow data for your application on request.
| Model | AirTAC GR200-06 Pressure Regulator (GR20006F2) |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Mounted at a wall drop to give technicians a locally adjustable psi-regulated supply for impact drivers, ratchets and die grinders at the bench.
Regulates the small air cylinders that raise and hold a pressure-sensitive labeler's applicator head, with setpoints read directly in psi on the line.
Sets the cylinder pressure that tensions web material through a converting machine's nip rollers, letting operators tune tension without touching the main header.
Take the 200 size in 1/8 in for small branches and compact actuators; step up to 300, 400 or 600 as ports and flow demand increase. This version's F2 gauge is the square style scaled in psi, so it reads the same units as US plant gauges; F1 (MPa) and C3 (round, bar) serve other conventions. The thread is PT as standard, with G (BSPP) and NPT available to order when your piping needs them. A bracket is included unless the J suffix is specified, and the L low-pressure type handles setpoints up to 0.4 MPa. Because flow is published as curves and not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC gives GR flow performance as curves rather than one rated number, so quoting a single figure would be guesswork. Provide your inlet pressure, setpoint and air demand and we will confirm the datasheet flow data for this 1/8 in model on request.
Only the gauge scale: F2 uses the embedded square gauge reading in psi, while F1 reads in MPa. The regulator itself - 200 size, 1/8 in PT port, 0.05-0.9 MPa (7-130 psi) adjustment range and standard type - is the same.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.