The AirTAC AirTAC GR200-06 Pressure Regulator (GR20006JF1) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The GR20006JF1 is an AirTAC G-series air pressure regulator for compressed air only: it steps supply pressure down to your set point and holds it steady downstream. It is a regulation-only unit with no filter, bowl or lubricator, so use upstream filtration where the air needs drying or cleaning. This size 200 configuration has PT1/8 ports, the embedded square gauge with an MPa scale, and the J code means no mounting bracket is included.
This is a genuine AirTAC part from the GR series, offered in sizes 200 through 600 with alternative ports, gauge styles and scales, a low-pressure (L) version and an optional reverse/check valve (K). Maximum inlet pressure is 1.0 MPa (145 psi), the setting range is 0.05-0.9 MPa (7-130 psi), and the working temperature range is -20 to 70 C. Flow figures are published as curves, not a single rating, so we confirm flow and datasheet details on request.
| Model | AirTAC GR200-06 Pressure Regulator (GR20006JF1) |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Supplied without bracket |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Regulates the air feed to small pneumatic grippers and cylinders on compact assembly modules where the set pressure must stay put between cycles.
Supplies pop-up stops and gate cylinders on conveyor cells at a fixed, repeatable pressure so product handling stays gentle and predictable.
Controls air to cutters, tensioners and cable guides on wire-processing equipment, keeping actuation pressure independent of supply fluctuations.
Set your regulation span first: the GR20006JF1 covers 0.05-0.9 MPa (7-130 psi) downstream from up to 1.0 MPa inlet, and if you need lower set points the L low-pressure variant is the catalogue choice. Size 200 with PT1/8 ports is the compact end of the range; move to sizes 300/400/600 for bigger ports and higher flow. This unit carries the embedded square gauge in MPa; round gauges and psi or bar scales are alternative order codes. Specify the G (BSPP) or T (NPT) suffix if your installation is not PT-threaded, and add the bracket option if you want it panel-mounted. Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
AirTAC does not publish a single rated-flow number for GR regulators - flow is given as performance curves. We do not state a figure here, but send us your application details and we will confirm the sizing from the datasheet curves on request.
That is purely a reading preference for your operators. F1 gives the embedded square gauge in MPa; C-type round gauges and psi or bar scales are available as alternative catalogue codes on the same regulator. Pick the scale your team checks most often, and tell us if you need help matching it to the rest of your panel.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.