The AirTAC AirTAC GR200-06 Pressure Regulator (GR20006LC1) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
GR20006LC1 is a genuine AirTAC G-series air pressure regulator for compressed air only, in the low-pressure type (code L): the setting range goes up to 0.4 MPa instead of the standard 0.05-0.9 MPa. The code decodes to a size 200 unit with a 1/8in PT-thread port (PT is the standard thread; G and NPT are orderable options), an external round pressure gauge with MPa scale (code C1), and the mounting bracket included. Maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -20 to 70 C. Pressure loss through the GR series is low.
The G-series regulator line is available in sizes 200, 300, 400 and 600, stepping ports from 1/8in to 1in. Options include the standard or low-pressure type, with or without a reverse (check) valve, no gauge, embedded square gauges, or external round gauges in MPa, psi or bar scales, and G or NPT threads. AirTAC publishes flow as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GR200-06 Pressure Regulator (GR20006LC1) |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure type | Low-pressure type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| L | Low-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.4 MPa (7 - 58 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Dials a low, gauge-checked pressure to a spray gun or coating head on a small finishing bench where a delicate low setting is needed.
Supplies low-pressure purge or actuation air to a lab analyzer panel, with the setting read directly on the round MPa gauge.
Sets reduced pressure for delicate sealing or labelling actuators, panel-mounted on the machine frame with the included bracket.
Pick the L low-pressure type like this unit when your working pressure sits well below the standard range; its setting tops out at 0.4 MPa. This build carries an external round gauge on an MPa scale (code C1) - order a C2/C3 variant for psi or bar instead. Size 200 with a PT1/8in port fits the smallest lines; GR300/400/600 step up to 1/4in-1in ports for more flow. G and NPT threads are orderable in place of PT, and the bracket is included here (code J omits it).
Flow is published as curves, not as one rated figure, so ask us to confirm the datasheet data against your application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
There is no single rated flow number: AirTAC publishes GR-series flow as performance curves. We do not quote a figure on this page, but we will confirm the flow and datasheet data for your application on request before you order.
L is the low-pressure type: the setting range tops out at 0.4 MPa, versus 0.05-0.9 MPa on the standard type. This unit also carries an external round gauge with MPa scale (C1) and includes the mounting bracket, while the base code has a gauge and bracket by default.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.