The AirTAC AirTAC GR200-06 Pressure Regulator (GR20006LF1K) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The AirTAC GR20006LF1K is a low-pressure type air pressure regulator in the G-series GR family. It reduces and holds downstream air pressure only - no filtration and no lubrication - and this unit is set up with a 1/8 in PT port, an embedded square pressure gauge reading in MPa, a built-in reverse (check) valve, and the mounting bracket included. As an L-type regulator, its set-pressure range goes up to 0.4 MPa. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the service temperature range is -20 to 70 C.
This is a genuine AirTAC part. The GR family is available in sizes 200, 300, 400 and 600 with a choice of ports, thread options (PT standard, G and NPT as catalogue options), gauge scale, bracket and check-valve configurations. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request.
| Model | AirTAC GR200-06 Pressure Regulator (GR20006LF1K) |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure type | Low-pressure type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| L | Low-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.4 MPa (7 - 58 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Gives a sealing or tucking station on a carton line its own gentle, repeatable air pressure, isolated from swings in the shop supply, with a local MPa gauge for setting.
Feeds a stable low-pressure pilot signal to pneumatic valve positioners and actuator circuits on a process skid, with the built-in check valve protecting the setting from back-pressure.
Lets a laboratory fixture or test rig run at a controlled low pressure well below the shop compressor setting, with a local gauge so operators set and verify the point each run.
Start with the port: the 200 size in this code carries a 1/8 in PT port, so check that your machine supply line is 1/8 in or plan a step up to GR300/GR400/GR600 for larger lines and higher air demand. This is the L (low-pressure) type, so choose it only where the process needs settings up to 0.4 MPa. Decide on gauge scale (MPa, psi or bar) and whether the reverse (check) valve - fitted on this code - is wanted. Thread is PT as standard; G (BSPP) and NPT are orderable options. Bracket is included on this code; J-coded versions omit it. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.
AirTAC publishes GR regulator flow as curves, not as a single rated figure, so we do not quote a number here. Tell us your line size and air demand and we will confirm the flow and datasheet figures for this exact model on request.
The L in the code marks the low-pressure regulator type: its set-pressure range goes up to 0.4 MPa instead of the standard 0.05-0.9 MPa range. This unit carries an embedded square gauge reading in MPa; psi and bar scales are available on other codes in the family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.