verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GR200 · Air Pressure Regulator

AirTAC GR200-06 Pressure Regulator (GR20006LJF1K)

The AirTAC AirTAC GR200-06 Pressure Regulator (GR20006LJF1K) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/8"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketSupplied without bracket
$41.37 $46.08Save 10% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GR200-06 Pressure Regulator (GR20006LJF1K)

GR20006LJF1K is an AirTAC G-series air pressure regulator: regulation only, with no filter element and no lubricator. This is the 200 size with a PT 1/8in port, the low-pressure (L) type whose setting range extends up to 0.4 MPa, an embedded square pressure gauge on an MPa scale, a built-in reverse/check valve (K), and no mounting bracket (J). It holds a stable downstream pressure from a compressed-air supply, with an operating temperature of -20 to 70 C.

This is a genuine AirTAC part, bought from the catalogue as an original component. The G-series regulator line runs from size 200 up to 600, with larger port sizes, PT/G/NPT thread options, standard or low-pressure regulation, gauge and reverse-valve options, and bracket choices. Because rated flow for these units is published as curves rather than a single figure, we confirm the datasheet flow numbers for your application on request.

AirTAC GR200-06 Pressure Regulator (GR20006LJF1K) Technical Specifications

ModelAirTAC GR200-06 Pressure Regulator (GR20006LJF1K)
SeriesGR200 pressure regulator
Port sizePT1/8" (PT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GR200-06 Pressure Regulator (GR20006LJF1K)

GR200G-series pressure regulator, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/8" · 0.05 - 0.4 MPa (7 - 58 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GR200-06 Pressure Regulator (GR20006LJF1K) Is Used

valve

Pneumatic clamping on a small fixture

Set and hold a low clamping pressure on an air-actuated clamp cylinder in a machining fixture, where the low-pressure (L) range up to 0.4 MPa is the working band.

science

Bench-scale laboratory air lines

Regulate instrument-grade compressed air on a laboratory bench setup or pilot rig, with the built-in check valve preventing backflow into the supply line.

tune

Setpoint tuning on packaging machines

Give a packaging or labelling machine a dedicated 1/8in pressure-adjust point for a light-duty actuator, with the MPa gauge making the setpoint easy to read and verify.

Is the AirTAC GR200-06 Pressure Regulator (GR20006LJF1K) the Right Regulator?

The 200 size with a 1/8in port is the smallest step in the GR line, so match it to a circuit whose required flow sits comfortably in the low end of the G-series flow curves - step up to 300, 400 or 600 if your demand is higher. The low-pressure (L) type in this code covers regulation up to 0.4 MPa; if your setpoint needs more, order the standard type instead. You also have real choices on gauge (square embedded, round external, MPa/psi/bar scale), reverse/check valve, bracket, and PT versus G or NPT thread.

Because AirTAC publishes flow as curves rather than a single rated number, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

AirTAC GR200-06 Pressure Regulator (GR20006LJF1K) FAQ

AirTAC does not publish a single rated flow figure for GR regulators - flow is given as performance curves. Send us your line pressure and air demand and we will confirm the datasheet flow figures for this exact unit on request before you order.

The L in the code selects the low-pressure variant of the GR regulator: its adjustment range extends up to 0.4 MPa instead of the standard type's range. Everything else - the 200 size, PT 1/8in port, square MPa gauge, check valve and no-bracket configuration - decodes exactly as written in the model number.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GR200-06 Pressure Regulator (GR20006LJF1K)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR20006LJF1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.