The AirTAC AirTAC GR400-10 Pressure Regulator (GR40010LN) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT3/8" ports, ordered without a gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
GR40010LN is an AirTAC G-series air pressure regulator in the 400 size, fitted with a 3/8 in PT threaded port. The L marks the low-pressure type, with the regulated outlet set up to 0.4 MPa, suited to circuits that run below the standard GR range. The bracket position is blank in this code, so a mounting bracket is included; the N code means no gauge is fitted, so set pressure is read on a separate gauge. The GR is also panel-mountable.
This is a genuine AirTAC part. The GR series is offered in 200, 300, 400 and 600 sizes with a choice of PT, G(BSPP) or NPT threads, gauged or gaugeless versions, bracket or bracketless configurations, and an optional reverse/check valve. It runs on compressed air only, works from -20 to 70 C, and maximum working pressure is 1.0 MPa (145 psi). Flow is published as curves rather than a single rating, so we confirm the datasheet figures on request.
| Model | AirTAC GR400-10 Pressure Regulator (GR40010LN) |
|---|---|
| Series | GR400 pressure regulator |
| Port size | PT3/8" (PT thread) |
| Regulating range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure type | Low-pressure type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR400 | G-series pressure regulator, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| L | Low-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR400 · PT3/8" · 0.05 - 0.4 MPa (7 - 58 psi) |
|---|---|
| One size down | GR300 |
| One size up | GR600 |
| Line order | Filter first, then regulator, then lubricator |
Mounted on the bracket at a workshop air drop to hold a low, fixed working pressure for hand-held pneumatic tools and blowlamps.
Used on a maintenance bench to feed low test pressure into trailer brake harness fittings, where the set point stays under 0.4 MPa.
Regulates low-pressure air fed into duct-blowing and cable-pulling rigs on telecom installation sites, panel- or bracket-mounted at the compressor outlet.
Size 400 with a 3/8 in PT port sits in the upper-middle of the GR range; drop to 300 or step to 600 when your flow requirement points to a different port size. As an L-type regulator the outlet is adjustable up to 0.4 MPa, so choose the standard GR for set points above that. This version keeps the mounting bracket (the J code deletes it) and ships without a gauge - order a C or F variant if you need the pressure readable at the unit. Thread is PT as the standard, with G(BSPP) and NPT available to order. AirTAC publishes flow as curves, not a single rated figure, so ask us to confirm sizing against the application before ordering.
Quick checklist
Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.
No. The N code means no gauge is fitted, so read the set pressure on a separate gauge in the circuit. If you want the pressure readable at the unit, order the GR40010LJC1 (round gauge) or GR40010LJF1 (square gauge) variant; this version does include the mounting bracket.
AirTAC publishes GR flow only as characteristic curves, not as a single rated figure, so we do not quote a number here. Send us your required flow and operating pressures and we will confirm the GR400 datasheet figures and correct port size on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.