verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GR400 · Air Pressure Regulator

AirTAC GR400-15 Pressure Regulator (GR40015JF3)

The AirTAC AirTAC GR400-15 Pressure Regulator (GR40015JF3) is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/2" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadPT
  • BracketSupplied without bracket
$47.97 $52.85Save 9% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GR400-15 Pressure Regulator (GR40015JF3)

The GR40015JF3 is an AirTAC G-series air pressure regulator: pressure regulation only, with no filter bowl and no lubricator. This 400-size unit carries a 1/2 in PT port and an embedded square pressure gauge reading in bar. It reduces and holds downstream pressure for actuators and air tools, with a set-point range of 0.05-0.9 MPa. The medium is compressed air, with a maximum working (inlet) pressure of 1.0 MPa (145 psi) and an operating temperature range of -20 to 70 C (non-freezing).

This is a genuine AirTAC part. The GR series spans sizes 200, 300, 400 and 600, with a choice of port sizes, square or round external gauges, MPa/psi/bar scales, a low-pressure version and an optional reverse (check) valve; the J code here means no mounting bracket is fitted, and the body is also panel-mountable. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.

AirTAC GR400-15 Pressure Regulator (GR40015JF3) Technical Specifications

ModelAirTAC GR400-15 Pressure Regulator (GR40015JF3)
SeriesGR400 pressure regulator
Port sizePT1/2" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — square, bar scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GR400-15 Pressure Regulator (GR40015JF3)

GR400G-series pressure regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR400 · PT1/2" · 0.05 - 0.9 MPa (7 - 130 psi)
One size downGR300
One size upGR600
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GR400-15 Pressure Regulator (GR40015JF3) Is Used

precision_manufacturing

Pneumatic press clamping

Setting a repeatable clamping pressure on the air cylinder of a bench pneumatic press or workholding fixture, so parts are gripped at the same force every cycle.

factory

Packaging line actuators

Feeding regulated air to the pick-and-place cylinders and grippers on a carton-forming or filling line, isolated from swings in the shop-air supply header.

settings_input_component

CNC machine air drop

Point-of-use pressure control on the air drop of a CNC machining centre, setting a fixed supply pressure for the tool-change and clamping circuits.

Is the AirTAC GR400-15 Pressure Regulator (GR40015JF3) the Right Regulator?

This is the 400 size in the GR range, with a 1/2 in PT port. Step up to 600 or down to 300/200 to match pipe size and air demand. The set-point range is 0.05-0.9 MPa, and the built-in square gauge reads in bar; choose GR40015JF1 for an MPa-scale gauge or the scale-2 code for psi. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options. The J code means the mounting bracket is not included - request the bracket option if you plan to panel-mount.

Flow for GR regulators is published as curves, not a single rated figure, so we do not quote one number. Tell us your supply pressure, set point and air consumption and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

AirTAC GR400-15 Pressure Regulator (GR40015JF3) FAQ

AirTAC publishes GR flow data as curves, not as a single rated figure, so we do not quote one number. Send us your supply pressure, set point and air demand and we will confirm the sizing and flow figures from the datasheet before you order.

Scale 1 gauges read in MPa, scale 2 in psi and scale 3 in bar. GR40015JF3 is supplied with an embedded square gauge reading in bar; choose GR40015JF1 for MPa or the scale-2 code for psi. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GR400-15 Pressure Regulator (GR40015JF3)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GR40015JF3 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.