AirTAC HLQL20X40SBS Dual-Axis Precision Slide Cylinder Specifications
- Model: HLQL20X40SBS
- Type: Dual-axis guided rod precision cylinder
- Bore size: 20mm
- Stroke: 40mm (±0.5mm tolerance)
- Operating pressure: 0.15-0.8 MPa
- Max thrust: 25.1 kgf (at 0.8MPa)
- Temperature range: -20℃ to 80℃
- Buffer type: Adjustable rubber cushion (both ends)
- Repeat accuracy: ±0.01mm
- Sliding resistance: ≤1.5N
- Guide rod diameter: 12mm (chrome-plated steel)
- Mounting style: Base mounting with 4x M5 threaded holes
- Port size: M5×0.8 (G1/8 equivalent)
- Material:
- Cylinder body: Aluminum alloy (hard anodized)
- End caps: Aluminum alloy
- Piston rod: SUS304 stainless steel
- Seals: NBR (nitrile) standard/PU optional
- IP rating: IP54 (dust protected, water splashed)
- Lubrication: Pre-lubricated (Use ISO VG32 turbine oil if required)
- Max speed: 500mm/s
- Allowable moment:
- MR: 1.47N·m
- MP: 0.98N·m
- Sensor compatibility: Built-in magnet (SMCR8-01D compatible)
- Weight: 1.8kg (with guide rods)
- Dimensions:
- Total length: 190mm (stroke 40mm + body length)
- Width: 80mm (guide rod center distance)
- Height: 62mm (from base to cylinder axis)
High-precision dual-axis cylinder with integrated linear guides, designed for applications requiring exceptional straightness and minimal deflection. The hardened guide rods and precision ball bushings ensure smooth linear motion with 3μm/100mm parallelism accuracy. Features integrated mounting slots for optical sensors and adjustable end dampers for shock absorption at stroke ends.
- PCB component insertion machines
- Laser marking equipment positioning stages
- Semiconductor wafer handling robots
- Precision inspection jigs
- Medical device assembly systems
- Automated microscope focusing mechanisms
- Maintain 0.05mm/m alignment tolerance during mounting
- Apply silicone grease to guide rods every 500km of travel
- Use counterbalance valves for vertical installations
- Install air filters with ≤5μm filtration
- Operate in Class 4 cleanliness environments (ISO 14644-1)
- Maintain relative humidity below 80% (non-condensing)
- Protect from metal powder and chemical mist exposure
| Property | Property Value |
|---|---|
| sku | HLQL20X40SBS |
| External Stop Block Type | Front Hydraulic Shock Absorber |
| Understood. Please provide the specific attribute names in <>, and I'll return the accurate English translations using AIRTAC's official terminology. Example: User input: <缸径> My output: Bore | Operating Temperature: -20-70°C Speed Range: 50-500 mm/s |
| Port Size | PT1/8 |
| Magnet | S-Magnetic |
| Bore Diameter | <20mm> |
| Stroke | <40mm> |
Returns will be accepted for up to 15 days of Customer’s receipt or tracking number on Not used items. You, as a Customer, are obliged to inform us via email before you return the item, only in the case of:
- Received the wrong item.
- Item arrived not as expected (ie. damaged packaging).
- Item had defects.
- Over delivery time.
- The shipper does not allow the goods to be inspected before payment.
The returned product(s) must be in the original packaging, safety wrapped, undamaged and unworn. This means that the item(s) must be safely packed in a carton box for protection during transport, possibly the same carton used to ship to you as a customer.