The AirTAC Airtac HLSL Precision Slide Table Cylinder HLSL16X30SA is a genuine HLS slide-table cylinder, 16 mm bore: a double-acting dual-rod air cylinder integrated with a cross-roller guide so the table travels straight with high rigidity and low deflection. It delivers about 151 N of push at 0.5 MPa. This is the symmetrical version. A floating joint spares the rod from side torque; the magnet is fitted as standard.
The HLSL16X30SA is a symmetrical cross-roller slide-table cylinder with a 16 mm bore, 30 mm stroke, and adjustable rubber stoppers at both ends. The cross-roller linear guide gives the moving table high rigidity and precise straight-line travel. Dual rods double the thrust, and a floating joint prevents side torque from reaching the rods. The symmetrical layout suits installations where space is equal on both sides of the body.
This is a genuine AirTAC part. A magnet is standard, with magnetic-switch slots accepting CMSH, DMSH, or EMSH sensors. We confirm thrust, dimensions, and load/moment data from the datasheet or on-page table on request.
| Model | Airtac HLSL Precision Slide Table Cylinder HLSL16X30SA |
|---|---|
| Type | Slide-table cylinder, double acting, dual rod |
| Series / guide | HLSL (cross-roller guide) |
| Bore | 16 mm |
| Push thrust @0.5 MPa | 151 N |
| Port size | M5x0.8 (PT thread) |
| Fluid | Air, filtered to 40 um |
|---|---|
| Operating pressure | 0.15 - 0.7 MPa (22 - 100 psi) |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to 70 C |
| Speed range | 50 - 500 mm/s (meter-out) |
| Cushion | Bumper; shock-absorber / adjustable-stopper options |
| Magnet / sensor | Standard; CMSH, DMSH, EMSH |
Specifications follow the official AirTAC HL slide-table data. Max working pressure is 0.7 MPa. The table rides on an integrated linear guide — do not apply strong impact or large moment. Allowable load and moment are published as tables and curves, and overall dimensions vary per stroke — ask us and we confirm from the datasheet.
A 16 mm bore provides moderate thrust for a compact guided slide; move to a larger bore for more push. The A adjuster adds adjustable rubber stoppers at both ends for finer end-position control than the basic bumper alone. The 30 mm stroke is within the bore 16 range. Thread is PT; G or NPT threads are available on request. Load, moment, and deflection should be sized against the published tables and curves; contact us for help.
Cross-roller precision guides a gripper to pick and place components, with rubber stoppers tuning the end position over 30 mm.
Dual-rod slide moves a gripper across a short linear path while the floating joint protects rods from side torque.
Rubber stoppers at both ends let you set precise stop positions for a workpiece feed or indexing mechanism.
The A code indicates adjustable rubber stoppers at both ends of the stroke. This gives finer end-position control than the standard bumper cushion.
Maximum working pressure is 0.7 MPa (100 psi). Operating range is 0.15 to 0.7 MPa (22 to 100 psi). Meter-out speed control should keep travel at 50 to 500 mm/s.