The AirTAC Airtac HLSL Precision Slide Table Cylinder HLSL20X10SBS is a genuine HLS slide-table cylinder, 20 mm bore: a double-acting dual-rod air cylinder integrated with a cross-roller guide so the table travels straight with high rigidity and low deflection. It delivers about 236 N of push at 0.5 MPa. This is the symmetrical version. A floating joint spares the rod from side torque; the magnet is fitted as standard.
The HLSL20X10SBS is a symmetrical cross-roller slide table cylinder: a double-acting dual-rod air cylinder built onto an integrated cross-roller guide, so the table moves in a straight line with high rigidity and low deflection. The floating joint spares the rods from side torque, the symmetrical body gives two workpiece mounting orientations, and the dual rods provide the greater thrust of a twin-rod 20 mm bore. The BS ending means a shock absorber is fitted on the extension side to absorb the working stroke, while the 10 mm stroke fits short indexing and positioning moves.
This is a genuine AirTAC part with the magnet fitted as standard for position detection; the body accepts CMSH, DMSH or EMSH magnetic switches in its slots. Ports are 1/8 inch. Operating pressure for this bore is 0.15-0.7 MPa (22-100 psi), the medium is air filtered to 40 um, and speed range is 50-500 mm/s. We confirm the exact thrust, dimensions and load-moment figures for this model from the datasheet or the on-page spec table on request.
| Model | Airtac HLSL Precision Slide Table Cylinder HLSL20X10SBS |
|---|---|
| Type | Slide-table cylinder, double acting, dual rod |
| Series / guide | HLSL (cross-roller guide) |
| Bore | 20 mm |
| Push thrust @0.5 MPa | 236 N |
| Port size | 1/8" (PT thread) |
| Fluid | Air, filtered to 40 um |
|---|---|
| Operating pressure | 0.15 - 0.7 MPa (22 - 100 psi) |
| Proof pressure | 1.2 MPa (175 psi) |
| Temperature | -20 to 70 C |
| Speed range | 50 - 500 mm/s (meter-out) |
| Cushion | Bumper; shock-absorber / adjustable-stopper options |
| Magnet / sensor | Standard; CMSH, DMSH, EMSH |
Specifications follow the official AirTAC HL slide-table data. Max working pressure is 0.7 MPa. The table rides on an integrated linear guide — do not apply strong impact or large moment. Allowable load and moment are published as tables and curves, and overall dimensions vary per stroke — ask us and we confirm from the datasheet.
Within the HLSL cross-roller family, bore 20 is the choice when the application needs more push than the 6 to 16 mm bores; the 10 mm stroke is within this bore's published stroke table. Order the BS code when the extending, working stroke is the one that hits hard, for example a quick push-into-place move; pick SB if both ends need shock absorbers, or A-type codes for adjustable rubber stoppers. This code is threaded PT, with G and NPT (T) alternatives. Send us the workpiece mass, its centre-of-gravity offsets and your cycle speed, and we will verify the slide against the published allowable-load, moment and kinetic-energy tables and the deflection curves.
Steps a small fixture between two assembly positions over 10 mm; the extension-side shock absorber decelerates the working stroke and the cross-roller guide holds position accuracy.
Pushes a finished part off a nest or pallet in a short, controlled move, with the dual-rod thrust keeping the push face parallel to the part.
Separates or spaces parts in a dividing fixture where the slide must stay square under load, benefiting from the rigid cross-roller guidance and symmetrical mounting.
The prefix sets the guide, and the guide sets the performance character. HLSL is a symmetrical cross-roller slide table for the highest precision, rigidity and load capacity. HLQ uses ball bearings and is anti-rust and dust-proof. HLH is a miniature roller-ball guide for the best straightness in a compact size, and HLF is a low-height cross-roller body for tight spaces. Keep to one sub-family when comparing thrust, because each has its own published thrust table.
No. The published speed range for this series is 50-500 mm/s, controlled meter-out, at an operating pressure within 0.15-0.7 MPa (22-100 psi) for this bore. Above that range the shock absorber and guide are outside their validated conditions. If you need more speed, tell us the application and we will help you size against the datasheet tables rather than exceeding the limits.